Caught or wedged between objects nonrunning · Amputations, avulsions, enucleations unspecified
At a glance
Federal OSHA recorded a severe workplace injury
at Michels Power, Inc., 665 Nutmeg Road N., SOUTH WINDSOR, CONNECTICUT 06074
on — Amputations, avulsions, enucleations unspecified, affecting the Other finger(s) n.e.c..
Final narrative
An employee was securing the claw of a grapple truck to the truck bed. His left little finger was caught between the tie down strap and the rub rail of the truck, resulting in partial amputation of the finger.
Amputation Other finger(s) n.e.c. Trucks with other mounted machinery, equipment n.e.c.
An employee was changing tooling on equipment and was aligning the tool when his finger was caught in an alignment hold for a locking pin. The employee sustained a fingertip amputation.
An employee was leaving the operator platform of a digger derrick. The employee stepped off their seat onto the catwalk and slipped on ice. The employee fell to the catwalk and the ground below, resulting in a forehead laceration and broken wrists.
An employee was changing a die in a press when the die slipped and crushed the employee's left index finger. The employee sustained an open facture of the tuft of the left distal phalanx and a partial amputation.
An employee was diagnosing the lack of flow of product to a powder bin. The employee removed the rotary star valve below the bin. While he was reinstalling the valve, his right middle finger was crushed between its shaft and its housing. The finger was partially amputated.
On October 30, 2025, an employee was working to adjust a stackable metal shipping container. As the container dropped into place, it caught the employee's hands in an area between the upper and lower cross-members. The employee suffered a laceration to the left ring finger that required stitches, bruising to the right ring finger, and fractures to the right middle finger that necessitated medical amputation of the fingertip.
An employee was changing the spacing on a telehandler's forks. A fork slipped, and the employee's left index finger was caught between it and the mast. The fingertip was medically amputated at the first knuckle.
An employee was conducting routine maintenance on a mixer. New lid pins had been installed, and the employee was rotating by hand to ensure they had been installed correctly. The employee's left middle finger was caught between the lid and top of a pin. The momentum from the mixer continued, causing a crushing injury to the finger. The employee underwent a medical amputation from the top knuckle to the tip of the finger.
More severe injuries in this industry (NAICS 237130)
An employee was terminating cables in a junction box. A loose ground wire came into contact with the bushing, causing a flash that burned the right side of the employee's face and his right hand.
An employee was using a bucket truck hoist to raise secondary aerial wiring. The wire made contact with the primary wire, causing an arc flash. The employee suffered burns to both hands and was hospitalized.
An employee was terminating conductors to buss bars inside the secondary compartment of a single-phase transformer. An arc flash occurred, causing burns to the soft tissue of the employee's face.
An employee was working to build an electrical substation. He was cleaning out the inside of a fixed section of a PVC pipe on the end that was furthest from an excavator. The excavator was outside of the trench and more than 25 feet away when it moved a pipe, pinching the employee's right arm between the two pipes. The employee's forearm was fractured.
An employee was checking on a machine outside of the building and removed a cover to clean out a blocked area. His hand was caught by a rotary valve in a dust collection machine. The employee's fingertip was amputated.
An employee was working to clean a glue roller with a scraper tool. The tool and the employee's left thumb were pinched between two rollers, resulting in a partial amputation.
An employee was re-arranging boxes of pipe insulation on a pallet. One of the boxes fell from the pallet and knocked over an upright empty cylinder. The cylinder fell and crushed the tip of the employee's right toe. The employee's toe required surgical amputation.
An employee was cutting extruded aluminum framing material using a horizontal band saw. She went to grab a rag in the machine when the rag contacted the blade and pulled her hand in toward the blade, resulting in a partial amputation of the right index finger.
An employee was using a cordless circular saw to relieve the long edge of a 1/2" rabbit cut on a 1 1/2" piece of chair rail trim. The piece of chair rail kicked out of the employee's hand and his left hand contacted the rotating saw blade. The employee's ring fingertip was amputated and he sustained lacerations to the middle, ring, and little fingers.