Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SINTON DAIRY FOODS COMPANY, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SINTON DAIRY FOODS COMPANY, LLC. in 3801 N SINTON RD, COLORADO SPRINGS, CO 80907 (NAICS 311511). OSHA activity number 306228701.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sinton Dairy Foods Company, LLC. — free Get an email when a new federal OSHA severe-injury report for Sinton Dairy Foods Company, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
3801 N SINTON RD
City
COLORADO SPRINGS
State
CO
ZIP
80907
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311511
SIC code (legacy)
2026
Employees
165
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Other-than-serious Gravity 10 1 instance 13 exposed
Issued
Mar 22, 2004
Abate by
May 6, 2004
Penalty
Initial $5,000 · Current $5,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment  which was free from
recognized hazards
which were likely to cause death or serious injury from fire and
explosion, in that, the
shutdowns and alarm devices of the Sullair Compressor, Model 20-125L - WC
AC 24KT,
Serial Number 003-84451, were not inspected and tested on a regular basis,
both high
temperature shut down switches were disabled and the output wires from the
thermistor
board to terminals 4 and 5 on the control panel had been jumpered.
Among other methods, one feasible and acceptable abatement method to
correct this
hazardous condition is to establish a periodic testing program in
accordance with paragraph
2.2.3 General Operating Procedures in ASME B19.1-1995 - Safety Standard
for Air
Compressor Systems.
Abatement Note:  Abatement certification and documentation is required for
this
item
(see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
  • — I (O) $5000.00
  • — Z (S) $5000.00

View Sinton Dairy Foods Company, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306228701.