Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: JEFFBOAT LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JEFFBOAT LLC in 1030 EAST MARKET STREET, JEFFERSONVILLE, IN 47130 (NAICS 336611). OSHA activity number 334290731.

Watch Jeffboat LLC — free Get an email when a new federal OSHA severe-injury report for Jeffboat LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JEFFBOAT LLC
Site address
1030 EAST MARKET STREET
City
JEFFERSONVILLE
State
IN
ZIP
47130
Mailing
P.O. BOX 610, JEFFERSONVILLE, IN 47130
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
750
Ownership type
A

4 citations on file for this inspection.

1910.179 J02

Deleted Serious Gravity 10 1 instance 12 exposed
Issued
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1910.179(j)(2):     Frequent inspection. The following items shall be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:    (a)  On All Crane Inspections - On or about February 17, 2012, a representative for Amclyde, the crane manufacturer, sent a letter dated February 17, 2012 to Jeffboat stating that crane CW3821 AKA Crane #1, had a worn out bores on the trunnion connection to the gantry crane and the keepers plates were not tight.  Jeffboat failed to exam and determine if the crane was still safe to operate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.305 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $4000.00 · Current $2400.00 Reduced
29 CFR 1910.305(b)(1)(ii):     Unused openings in boxes, cabinets, or fittings were not effectively closed or covered.    (a)  In Crane #8 In Electrical Area above Cab - On or about May 1, 2012, an item described as an transformer box was found not to have all of its openings covered.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.305 B02 I

Serious Gravity 5 2 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i):     All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    (a)  On Crane #81 - On or about May 1, 2012, the electrical box located above the cab on the left side of the crane was not covered.    (b)  On Crane #81 - On or about May 1, 2012, the light receptacle located outside of the cab was missing the bottom cover.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 F01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(f)(1):     Insulation. All conductors used for general wiring shall be insulated unless otherwise permitted in this subpart.    (a)  On Crane # 81 - On or about May 1, 2012, the electrical cable was cracked which leads to the maganet on Crane # 21.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View JEFFBOAT LLC's full OSHA safety record →