Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOLVAY IRON WORKS, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of SOLVAY IRON WORKS, INC. in 306 HIAWATHA BLVD WEST, SYRACUSE, NY 13204 (NAICS 238120). OSHA activity number 335302006.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Solvay Iron Works, INC. — free Get an email when a new federal OSHA severe-injury report for Solvay Iron Works, INC. is published. One employer, no account, unsubscribe in one click.
Site address
306 HIAWATHA BLVD WEST
City
SYRACUSE
State
NY
ZIP
13204
Mailing
3546 WALTERS ROAD, SYRACUSE, NY 13209
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
8
Ownership type
A

7 citations on file for this inspection.

1926.56 A

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 19, 2012
Abate by
Nov 2, 2012
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.56(a): While work was in progress, construction areas, ramps, runways, corridors, offices, shops or storage areas were not lighted to the minimum illumination intensities as listed in Table D-3 of 29 CFR 1926.56:    a) On or about 7/17/2012, Second Floor next to Dicks Store:  Employees were working in area without adequate lighting.  The area was illuminated at a level of 1.8 to 2.2 Lumens.      Abatement certification is required for this item.
Recent events (3)
  • — J (S) $1960
  • — C (S) $2800
  • — Z (S) $2800

1926.303 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 19, 2012
Abate by
Nov 2, 2012
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of American National Standards Institute, B7.1-1970, Safety Code for the Use, Care and Protection of Abrasive Wheels, and paragraph (d) of this section:    a) On or about 7/17/2012, "Pretty Girl" Store:  A Makita Grinder was used without a guard.    Abatement certification is required for this item.
Recent events (3)
  • — J (S) $1960
  • — C (S) $2800
  • — Z (S) $2800

1926.403 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 19, 2012
Abate by
Nov 2, 2012
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a) On or about 7/17/2012, "Pretty Girl" Store:  Power tools were energized through a relocatable power tap.     Abatement certification is required for this item.
Recent events (3)
  • — J (S) $1960
  • — C (S) $2800
  • — Z (S) $2800

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 19, 2012
Abate by
Nov 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.    a) On or about 7/17/2012, Second Floor next to Dicks Store:  A grinder and box fan were in use without a ground fault circuit interrupter or assured equipment grounding program in place.     Abatement certification is required for this item.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 19, 2012
Abate by
Nov 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) On or about 7/17/2012, Second Floor "Pretty Girl" Store:  A metal cased floor fan was not provided with a continuous path to ground.    b) On or about 7/17/2012, Second Floor next to Dicks Store:  A metal cased floor fan was not provided with a continuous path to ground.     Abatement certification is required for this item.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 F01

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 19, 2012
Abate by
Nov 2, 2012
Penalty
Initial $3,500 · Current $2,450 Reduced
29 CFR 1926.451(f)(1): Scaffold and/or scaffold components were loaded in excess of their maximum intended loads or rated capacities, whichever was less:    a) On or about 7/17/2012, "Pretty Girl" Store:  Two scissor lifts were loaded in excess of their posted load ratings.     Abatement certification is required for this item.
Recent events (3)
  • — J (S) $2450
  • — C (S) $3500
  • — Z (S) $3500

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 19, 2012
Abate by
Nov 2, 2012
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    a) On or about 7/6/2012, "Pretty Girl" Store:  An employee was working on top of a pipe rack exposed to falls of 15 feet without any fall protection.      Abatement certification is required for this item.
Recent events (3)
  • — J (S) $1960
  • — C (S) $2800
  • — Z (S) $2800

View Solvay Iron Works, INC.'s full OSHA safety record →