1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: CHALK MOUNTAIN SERVICES OF TEXAS LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHALK MOUNTAIN SERVICES OF TEXAS LLC in 8920 E STATE HWY 97, PLEASANTON, TX 78064 (NAICS 213112). OSHA activity number 338146210.

Watch Chalk Mountain Services OF Texas LLC — free Get an email when a new federal OSHA severe-injury report for Chalk Mountain Services OF Texas LLC is published. One employer, no account, unsubscribe in one click.
Site address
8920 E STATE HWY 97
City
PLEASANTON
State
TX
ZIP
78064
Mailing
8920 E STATE HWY 97, PLEASANTON, TX 78064
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
140
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 140 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4900.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees were exposed to inhalation hazards from hydrogen sulfide (H2S) gas. On or about January 4, 2013, and times prior thereto, the employer did not provide hydrogen sulfide (H2S) training to the sand operators and sand pushers when working in and around H2S gas. The employer did not provide any H2S monitoring equipment to the sand drivers and sand pushers when working in around areas where there is a potential for exposure to H2S gas. The employer did not conduct periodic testing of the H2S monitors that were provided to the water drivers.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.23 D01 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $2800.00 Reduced
29 CFR 1910.23(d)(1)(iv):  On stairways more than 44 inches wide but less than 88 inches wide, one handrail on each enclosed side and one stair railing on each open side:    a) On or about January 4, 2013, and times prior thereto, the employer failed to install hand rails on the stairs leading to the dispatchers office. The stairwell was approximately fifty six inches wide with sixteen steps.  Employee(s) are exposed to a fall hazard.       In the alternative:   29 CFR 1926.1052(c)(1)(i):Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4000

View CHALK MOUNTAIN SERVICES OF TEXAS LLC's full OSHA safety record →