Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BIG RIVER CYPRESS & HARDWOOD, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BIG RIVER CYPRESS & HARDWOOD, INC. in 19431 SR 71 NORTH, BLOUNTSTOWN, FL 32424 (NAICS 321113). OSHA activity number 338367634.

Watch BIG River Cypress & Hardwood, INC. — free Get an email when a new federal OSHA severe-injury report for BIG River Cypress & Hardwood, INC. is published. One employer, no account, unsubscribe in one click.
Site address
19431 SR 71 NORTH
City
BLOUNTSTOWN
State
FL
ZIP
32424
Mailing
P.O. BOX 189, BLOUNTSTOWN, FL 32424
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
27
Ownership type
A

8 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3570.00 · Current $2142.00 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:  a. On or about January 15, 2013, sawmill area was not kept free from excessive sawdust buildup on the walkways and around equipment.  Abatement Certification and Documentation are not required
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3570

1910.23 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1428.00 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard:  a. On or about January 15, 2013, sawmill area, the little edger area did not have a midrail, exposing the employee to moving equipment and fall hazards.  b. On or about January 15, 2013, deck near stairs, did not have a guardrail, exposing the employee to a 6.5 feet fall hazard.  Abatement Certification and Documentation are not required
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.24 H

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms:  a. On or about January 15, 2013, sawmill area, the stairs by the little edger did not have a mid-rail, exposing the employee to a 6.5 feet fall hazard.  Abatement Certification and Documentation are not required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II B

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1785.00 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  a. On or about January 15, 2013, the employer's written energy control procedures did not have clearly and specifically  outlined procedural steps to shut down, isolate, block and secure machines such as but not limited to the head rig, gang saw, chipper, resaw, roll cases, chains and conveyor belts.  Abatement Certification and Documentation are required
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

1910.147 C05 II D

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):  a. On or about January 15, 2013, supervisors were able to place locks on machines but their locks did not identify who placed the device on the machines.  Abatement Certification and Documentation are required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a. On or about January 15, 2013, the employer did not conduct an annual review of the energy control procedures since January 2010.    Abatement Certification and Documentation are required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1071.00 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a. On or about January 15, 2013, horizontal resaw, the junction box did not have a faceplate, exposing the employees to a fire hazard.  Abatement Certification and Documentation are not required
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.305 G02 III

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a. On or about January 15, 2013, there were exposed wires on the cord leading to the pin stop foot pedal, exposing the employees to electric shock.  Abatement Certification and Documentation are not required
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View BIG RIVER CYPRESS & HARDWOOD, INC.'s full OSHA safety record →