DUTCH HARBOR, AK —
OSHA Inspection: THE FISHING COMPANY OF ALASKA, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THE FISHING COMPANY OF ALASKA, INC. in F/V ALASKA WARRIOR, DUTCH HARBOR, AK 99692 (NAICS 311712). OSHA activity number 338899842.
Where did this inspection happen?
- Establishment
- THE FISHING COMPANY OF ALASKA, INC.
- Site address
- F/V ALASKA WARRIOR
- City
- DUTCH HARBOR
- State
- AK
- ZIP
- 99692
- Mailing
- 580 NACHES AVENUE SW SUITE 100, RENTON, WA 98057
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311712
- Employees
- 48
- Ownership type
- A
Citations
4 citations on file for this inspection.
1915.89 C02
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1915.89(c)(2): The employer did not ensure the use of a tags-plus system to prevent energization or startup, or the release of hazardous energy, before any servicing was started. Offshore Systems Inc. Dock, F/V Alaska Warrior, factory area; on or about 10 February 2013 and times prior thereto, the employer did not use a lockout/tags-plus system before servicing the Tokai Head Cutter Machines, Model PHC-550. Four of the five machines: #1- PHC-550L, #2 - PHC-550R, #4 - PHC-550R and #5 - PHC-550R were energized. Machine #3 - PHC-550L, was not tagged and was not energized. This condition exposed employees to a caught in hazard.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1915.89 C07 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1915.89(c)(7)(iv): The lockout and tags-plus systems log did not contain the location of machinery, equipment, or system being serviced. Offshore Systems Inc. Dock, F/V Alaska Warrior; on or about 10 February 2013 and times prior thereto, the employer did not ensure the lockout/tags-plus coordinator maintained and administrated a continuous log of each lockout and tags-plus system. This condition exposed employees to a caught in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1915.89 O05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1915.89(o)(5)(ii): The employer did not retrain each employee, when there was a change in his/her job assignment that presented new hazards or required a greater degree of knowledge about the employer's lockout/tags-plus program or procedures. F/V Alaska Warrior: On or about 10 February 2013 and times prior thereto, the employer did not ensure the lockout/tags-plus coordinator was trained to accurately maintain a continuous log of each lockout and tags-plus system. This condition exposed employees to a caught in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1915.89 Q01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1915.89(q)(1): The employer did not ensure that the audit was performed by an authorized employee other than the one(s) currently using the energy-control procedure being reviewed. F/V Alaska Warrior: On or about 10 February 2013 and times prior thereto, the employer did not ensure the lockout/tags-plus program was audited annually. This condition exposed employees to a caught in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at THE FISHING COMPANY OF ALASKA, INC.
DUTCH HARBOR, AK—2015-02-11 00:00:00
THE FISHING COMPANY OF ALASKA, INC
DUTCH HARBOR, AK—2015-02-11 00:00:00
THE FISHING COMPANY OF ALASKA, INC
DUTCH HARBOR, AK—2013-02-10 00:00:00
THE FISHING COMPANY OF ALASKA, INC.
DUTCH HARBOR, AK—2011-02-13 00:00:00
THE FISHING COMPANY OF ALASKA INC
DUTCH HARBOR, AK—2011-02-13 00:00:00
THE FISHING COMPANY OF ALASKA INC
View THE FISHING COMPANY OF ALASKA, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311712)
ANACORTES, WA—2026-07-01 00:00:00
WA317991905 - TRIDENT SEAFOODS CORPORATION
BAY CITY, OR—2026-06-11 00:00:00
317744508 - PACIFIC OYSTER CO
EVERETT, WA—2026-04-13 00:00:00
WA317990716 - DEEP SEA FISHERIES INC
ANACORTES, WA—2025-10-07 00:00:00
WA317988174 - SUGIYO USA INC
BELLINGHAM, WA—2025-08-12 00:00:00
WA317987368 - Q SEA SPECIALTY SERVICES LLC
More inspections in AK
ANCHORAGE, AK—2026-07-10 00:00:00
AK, INC
ANCHORAGE, AK—2026-07-08 00:00:00
ONE STOP SERVICES
ANCHORAGE, AK—2026-07-08 00:00:00
ANGUS ENTERPRISES
ANCHORAGE, AK—2026-07-08 00:00:00
NORTHERN EXCAVATION & CONSTRUCTION, LLC
UNALASKA, AK—2026-07-07 00:00:00
UNISEA INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338899842.