1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: RIDG-U-RAK, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RIDG-U-RAK, INC. in 12340 GAY RD., NORTH EAST, PA 16428 (NAICS 337215). OSHA activity number 338929433.

Watch Ridg-U-Rak, INC. — free Get an email when a new federal OSHA severe-injury report for Ridg-U-Rak, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
RIDG-U-RAK, INC.
Site address
12340 GAY RD.
City
NORTH EAST
State
PA
ZIP
16428
Mailing
120 SOUTH LAKE STREET, NORTH EAST, PA 16428
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337215
Employees
54
Ownership type
A

9 citations on file for this inspection.

1910.23 C01

Serious Gravity 1 1 instance 54 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $2025.00 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing on all open sides:   a) Stateline facility, floor level where pallets are stored, next to the stairs to the production area.  On or about February 26, 2013, the gate, guarding the open side of the elevated floor, was not closed.  Personnel were exposed to a fall of 5 feet to the lower level when using the stairs to go between the floor levels.
Recent events (2)
  • — I (S) $2025
  • — Z (S) $2700

1910.151 C

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2700.00 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes was not provided within the work area for immediate emergency use:  a) Stateline facility, north end of building, on wall of parts washer in the production area.  On or about February 26, 2013, personnel worked with corrosive materials including, but not limited to, Chem Add 6310, Sealtex 1523NCS and Enprox 714, and the eye wash station was not maintained in that, the it was dirty and it spewed brown water when first activated.    b) Stateline facility, north end of building, on wall of parts washer in the production area.  On or about February 26, 2013, personnel worked with corrosive materials including, but not limited to, Chem Add 6310, Sealtex 1523NCS and Enprox 714, and the eye wash station was not inspected on a weekly basis.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $3600

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2700.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by ingoing nip points and rotating parts:  a) Stateline facility, roll forms area in the production area.  On or about February 26, 2013, the flat, metal rolls rotated when feeding into the forming machine.  The rolls were not guard to protect employees from being caught by the rotating roll or the ingoing nip-point created when the rolls are rotating.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $3600

1910.212 A02

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(a)(2): The machine guard was such that it offered an accident hazard in itself:   a) Stateline facility, roll forms area in the production area.  On or about February 26, 2013, the panes of the plexi-glass guard around the cutting operation of the metal forming machine were broken with jagged edges, creating a hazard in itself.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $2025.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling:   a) Stateline facility, paint room.  On or about February 26, 2013, a metal, knock-out electrical box was used in lieu of permanent wiring.  The metal box was not installed or used in accordance with the listing and/or labeling instructions in that, the box is designed to be mounted and not used in a portable fashion.
Recent events (2)
  • — I (S) $2025
  • — Z (S) $2700

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Each outlet box did not have a cover, faceplate, or fixture canopy:  a) Stateline facility, north wall in paint room.  On or about February 26, 2013, the 120 volt outlet did not have a cover.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

5(a)(1)

Serious Gravity 5 1 instance 54 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2700.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:  a.) Stateline Facility, Front Entrance to Building/Near Parking Area -- Natural Gas Main Located Between The Building And Parking Lot -- On or about February 26, 2013, personnel were potentially exposed to fire/explosion hazards from natural gas mains and associated piping that were not protected against physical damage.  A section of the natural gas main and its associated piping were not protected from being accidentally struck-by vehicles.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $3600

1910.22 A01

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition:  a) Stateline facility, packaging and shipping area.  On or about February 26, 2013, the sawdust found in the area around and below the Delta wood-cutting saw was not cleaned on a regular schedule and was allowed to accumulate.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.132 A

Other-than-serious 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for extremities, protective clothing and protective shields and barriers, was not maintained in a sanitary and reliable condition:  a) Stateline facility, Upright Welding area, north end of building.  On or about February 26, 2013, personnel conducting welding operations were using welding jackets and protective clothing that was not maintained in reliable condition in that, the jackets/clothing had burn holes and tape was utilized to patch rips and holes in the protective equipment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View RIDG-U-RAK, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338929433.