1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: RIDG-U-RAK, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of RIDG-U-RAK, INC. in 12340 GAY RD., NORTH EAST, PA 16428 (NAICS 337215). OSHA activity number 338980550.

Watch Ridg-U-Rak, INC. — free Get an email when a new federal OSHA severe-injury report for Ridg-U-Rak, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
RIDG-U-RAK, INC.
Site address
12340 GAY RD.
City
NORTH EAST
State
PA
ZIP
16428
Mailing
120 SOUTH LAKE STREET, NORTH EAST, PA 16428
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337215
Employees
54
Ownership type
A

3 citations on file for this inspection.

1910.107 I08

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2700.00 Reduced
29 CFR 1910.107(i)(8): ):  Electrical equipment for electrostatic hand spraying was not so interlocked with the ventilation of the spraying area(s) that the equipment cannot be operated unless the ventilation fan(s) are in operation:  a.) Powder Coating - Company employees conducted powder coating operations in the Company's powder coating booth throughout each workshift.  On or about, and dates prior to, July 19, 2013, electrostatic hand-held spray guns were operable when the ventilation fans were not in operation.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $3600

1910.134 F02

Serious Gravity 1 2 instances 2 exposed
Issued
Penalty
Initial $2700.00 · Current $2025.00 Reduced

Hazardous substances 9135

29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:   a.) Ridg-U-Rak, Inc.-  The employer had not ensured that employees required to utilize North brand tight-fitting air purifying respirators, during powdercoating operations, were fit-tested annually. Employees were last fit tested September, 2002.
Recent events (2)
  • — I (S) $2025
  • — Z (S) $2700

1910.134 K05

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(5): Respiratory protection retraining was not conducted annually:  a.) Ridg-U-Rak, Inc.-  The employer had not ensured that employees required to use North brand tight fitting air purifying respirators received respiratory protection training annually. The employer and employees were unable to affirm when training was last received.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View RIDG-U-RAK, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338980550.