OSHA Inspection: FOREST SERVICE, RIGDON FLATCREEK FACILITY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOREST SERVICE, RIGDON FLATCREEK FACILITY in 49098 SALMON CREEK ROAD, OAKRIDGE, OR 97463 (NAICS 115310). OSHA activity number 338982887.

Watch Forest Service, Rigdon Flatcreek Facility — free Get an email when a new federal OSHA severe-injury report for Forest Service, Rigdon Flatcreek Facility is published. One employer, no account, unsubscribe in one click.
Site address
49098 SALMON CREEK ROAD
City
OAKRIDGE
State
OR
ZIP
97463
Mailing
49098 SALMON CREEK ROAD, OAKRIDGE, OR 97463
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
115310
Employees
50
Ownership type
D

8 citations on file for this inspection.

1910.213 B03

Serious Gravity 1 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.213(b)(3):   Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:  (a) On or about March 26, 2013 the inspection revealed that employees were potentially exposed to serious injury from the use of the Delta Drill Press, serial number 94B70502, without a device to prevent automatic restart. The drill press was located in the NE corner of the East Bay/Engine Bay at the Rigdon/Flatcreek Facility.
Recent events (1)
  • — Z (S) $0

1910.181 D03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.181(d)(3)(i): Complete inspections of the derrick were not performed at intervals as generally defined in paragraph (d)(1)(ii)(b) of this section depending upon its activity, severity of service, and environment, or as specifically indicated:  (a) On or about March 26, 2013 the inspection revealed that employees were potentially exposed to serious injury from the use of a derrick that had not been inspected as required by the regulation for several years. The derrick was located in the south yard at the Rigdon Flatcreek facility.
Recent events (1)
  • — Z (S) $0

1910.181 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.181(f)(1):   The employer did not ensure that a preventative maintenance program based on the derrick manufacturer's recommendations was established.  (a) On or about March 26, 2013 the inspection revealed that employees were potentially exposed to serious injury from the use of a derrick that was not maintained according to manufacturer recommendations. The derrick was located in the south yard of the Rigdon Flatcreek Facility.
Recent events (1)
  • — Z (S) $0

1910.181 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.181(g)(1):   The employer did not ensure that thorough inspection of all ropes in use was made at least once a month nor that a certification record which included the date of inspection, the signature of the person who performed the inspection, and an identifier for the ropes which were inspected was prepared and kept on file where readily available. The employer did not ensure that any deterioration, resulting in appreciable loss of original strength was be carefully observed and determination made as to whether further use of the rope would constitute a safety hazard:  (a) On or about March 26, 2013 the inspection revealed that employers were potentially exposed to serious injury from the use of a derrick where regular inspections were not performed on the condition of the wire running rope. The derrick was located in the south yard of the Rigdon Flatcreek Facility.
Recent events (1)
  • — Z (S) $0

1910.181 J02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.181(j)(2)(ii):   The employer did not ensure that a safety latch type hook was used whenever possible.   (a) On or about March 26, 2013 the inspection revealed that the employer allowed the use of a derrick rigged with a hook that did not have a safety latch. The derrick was located in the south yard at the Rigdon Flatcreek facility.
Recent events (1)
  • — Z (S) $0

1910.23 E02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.23(e)(2):   Stair rails did not consist of a top rail, intermediate rail and/or posts, with the vertical height not more than 34 inches (86.36 cm) nor less than 30 inches (76.2 cm) from upper surface of top rail to surface of tread in line with face of riser at forward edge of tread:  (a) On or about March 26, 2013 the inspection revealed that the staircase in the road crew shop at the Rigdon Flatcreek facility did not have a midrail.
Recent events (1)
  • — Z (O) $0

1910.37 B02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2):   Each exit was not clearly visible and marked by a sign reading Exit:  (a) On or about March 26, 2013 the inspection revealed an exit doorway that was not marked with a sign reading exit. The doorway was located in the NE corner of the road maintenance shop at the Ridgon Flatcreek facility.
Recent events (1)
  • — Z (O) $0

1910.303 B07 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(7)(iv):   There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemcial action or overheating.    (a) On or about March 26, 2013 the inspection revealed an outlet designed for use outdoors in a wet environment that had the outer cover broken off. The outlet was located outside in the front of the road crew shop building at the Rigdon Flatcreek facility.
Recent events (1)
  • — Z (O) $0