Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DRAGON ESP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DRAGON ESP in 10834 STATE HWY 53, SPRINGER, OK 73458 (NAICS 332420). OSHA activity number 339517484.

Watch Dragon ESP — free Get an email when a new federal OSHA severe-injury report for Dragon ESP is published. One employer, no account, unsubscribe in one click.
Establishment
DRAGON ESP
Site address
10834 STATE HWY 53
City
SPRINGER
State
OK
ZIP
73458
Mailing
10834 STATE HWY 53, SPRINGER, OK 73458
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
95
Ownership type
A

4 citations on file for this inspection.

1910.146 C04

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1500.00 Reduced
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:       On or about December 10, 2013, and at times prior thereto, at the establishment employees were required to enter permit required confined spaces but the employer did not develop and implement a written permit space entry program that complied with CFR 1910.146.  Employees were exposed to inhalation and trip and fall hazards that could result from the blasting operation.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2550

1910.253 B04 III

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1500.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:       On or about December 10, 2013, and at times prior thereto, at the compressed gas storage area near the Antec building, oxygen and acetylene cylinders were found stored together without a noncombustible barrier.  Employees were exposed to the hazard of fire.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $2550

1910.254 D09 III

Other-than-serious 2 instances 9 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1500.00 Reduced
29 CFR 1910.254(d)(9)(iii): Joining lengths of work and electrode cables were not done by the use of connecting means specifically intended for the purpose:      On or about December 10, 2013, and at times prior thereto, in the Dragon building two welding ground cables were spliced by just using electrical tapes wrapped around the cables and bare conductors were evident.  Employees were exposed to electrical shock.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $2550

1910.22 A02

Other-than-serious 2 instances 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:   On or about December 10, 2013, and at times prior thereto, water leaks from ceiling were observed on the floors in the Dragon and Antec building.  Employees were exposed to slip hazard created by standing water.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View DRAGON ESP's full OSHA safety record →