ALLISON PARK, PA —
OSHA Inspection: FORMS AND SURFACES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FORMS AND SURFACES, INC. in 4318 BRYANT ROAD, ALLISON PARK, PA 15101 (NAICS 339950). OSHA activity number 339567240.
Where did this inspection happen?
- Establishment
- FORMS AND SURFACES, INC.
- Site address
- 4318 BRYANT ROAD
- City
- ALLISON PARK
- State
- PA
- ZIP
- 15101
- Mailing
- 4318 BRYANT ROAD, ALLISON PARK, PA 15101
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339950
- Employees
- 37
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.242 B
- Issued
- Penalty
- Initial $1785.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) Facility, Compressed Air Nozzles: On or before January 30, 2014, employees used nozzles for cleaning workstations and parts with a regulated house air pressure measured above 30 psi.
Recent events (2)
- — I (S) $0
- — Z (S) $1785
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Facility, Manual Routing Table: On or before January 30, 2014, employees were exposed to fire and/or arcing part hazards in that a type NM-B cable clamp was used in lieu of a flexible cord connector at a metal utility box.
Recent events (2)
- — I (O) $1600
- — Z (S) $1785
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Facility, Manual Table Router: On or before January 30, 2014, employees were exposed to fire and/or arcing part hazards in that a flexible power cord was being used in lieu of permanent wiring. (b) Facility, Jet Turret Milling Machine: On or before January 30, 2014, employees were exposed to fire, arcing part, and/or tripping hazards in that a flexible power cord was being used in lieu of permanent wiring.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.305 A02 IX
- Issued
- Penalty
- Initial $1785.00 · Current $1600.00 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard: (a) Facility, Routing Table Light: On or before January 30, 2014, employees were exposed to arcing part and/or electrical shock hazards in that the fluorescent light bulb was not protected from incidental contact.
Recent events (2)
- — I (S) $1600
- — Z (S) $1785
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Facility, Jet Turret Milling Machine: On or before January 30, 2014, employees were exposed to machined material being ejected from the equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at FORMS AND SURFACES, INC.
PITTSBURGH, PA—2023-01-06 00:00:00
FORMS AND SURFACES, INC.
PHOENIX, AZ—2018-01-10 00:00:00
FORMS AND SURFACES, INC.
CARPINTERIA, CA—2017-08-09 00:00:00
FORMS AND SURFACES, INC.
ALLISON PARK, PA—2014-01-21 00:00:00
FORMS AND SURFACES, INC.
View FORMS AND SURFACES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339950)
APEX, NC—2026-07-07
161498 - SEVEN SPRINGS, INC.
MINNEAPOLIS, MN—2026-06-30
111500 - SIGNMINDS INC
ANGIER, NC—2026-06-29
161462 - CAROLINA SIGN AND SERVICE, LLC
GREENE, NY—2026-06-17
RAPP SIGNS, INC.
LEXINGTON, KY—2026-06-11
69225 - INTEGRATED SIGN - GRAPHIC INC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339567240.