Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISION RESISTOR CO., INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PRECISION RESISTOR CO., INC. in 10601 75TH ST. N., LARGO, FL 33777 (NAICS 334416). OSHA activity number 340048255.

Watch Precision Resistor CO., INC. — free Get an email when a new federal OSHA severe-injury report for Precision Resistor CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
10601 75TH ST. N.
City
LARGO
State
FL
ZIP
33777
Mailing
10601 75TH ST. N., LARGO, FL 33777
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334416
Employees
32
Ownership type
A

4 citations on file for this inspection.

1910.1025 D02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced

Hazardous substances 1591

29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level:  a) Solder Room - No assessment was conducted for the solder pot operation, on or about October 30, 2014.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.1025 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced

Hazardous substances 1591

29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:   a) Solder Room - There were 253.5 ug/100 cm2 on the top shelf next to the solder pot and 3.78 ug/100 cm2 on the portable cart handle, on or about October 3, 2014.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.1025 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced

Hazardous substances 1591

29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025:   a) Solder Room - There was no training conducted, on or about October 30, 2014.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 1591

29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a) Solder Room - Filtering face pieces were worn voluntarily and the information contained in Appendix D was not provided, on or about October 30, 2014.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PRECISION RESISTOR CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340048255.