1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: TCI, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TCI, LLC. in W132 N10611 GRANT DRIVE, GERMANTOWN, WI 53022 (NAICS 334416). OSHA activity number 348606203.

Watch TCI, LLC. — free Get an email when a new federal OSHA severe-injury report for TCI, LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
TCI, LLC.
Site address
W132 N10611 GRANT DRIVE
City
GERMANTOWN
State
WI
ZIP
53022
Mailing
W132 N10611 GRANT DR, GERMANTOWN, WI 53022
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334416
Employees
197
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 11 instances 11 exposed
Issued
Abate by
Penalty
Initial $14895.00 · Current $8937.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) On or about November 20, 2026, the employer did not ensure that the Winder #1 ULTI- M.E.T. (model no. 400, serial no. 97387) was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.  (b) On or about November 20, 2026, the employer did not ensure that Winder #2 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.  (c) On or about November 20, 2026, the employer did not ensure that Winder #3 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.  (d) On or about November 20, 2026, the employer did not ensure that Winder #4 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.  (e) On or about November 20, 2026, the employer did not ensure that Winder #5 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.  (f) On or about November 20, 2026, the employer did not ensure that Winder #6 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.  (g) On or about November 20, 2026, the employer did not ensure that Winder #7 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.  (h) On or about November 20, 2026, the employer did not ensure that Winder #8 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.  (i) On or about November 20, 2026, the employer did not ensure that Winder #9 was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.  (j) On or about November 20, 2026, the employer did not ensure that Winder #12 Armature Coil Equipment, Inc. Coil Winder (model no. 3UPAS-II, serial no. W127822-1) was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.  (k) On or about November 20, 2026, the employer did not ensure that Winder #13 Armature Coil Equipment, Inc. Coil Winder (model no. 3UPAS-II, serial no. W127822-2)was provided with adequate guarding to protect employees from injury from the rotating face plate and attached mounting fixture during the operation of the unit creating an entanglement hazard.
Recent events (2)
  • — I (S) $8937
  • — Z (S) $14895

1910.212 A03 II

Serious Gravity 10 11 instances 11 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):   (a) On or about November 20, 2026, the employer did not ensure that the Winder #1 ULTI- M.E.T. (model no. 400, serial no. 97387) was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.  (b) On or about November 20, 2026, the employer did not ensure that Winder #2 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.  (c) On or about November 20, 2026, the employer did not ensure that Winder #3 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.  (d) On or about November 20, 2026, the employer did not ensure that Winder #4 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.  (e) On or about November 20, 2026, the employer did not ensure that Winder #5 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.  (f) On or about November 20, 2026, the employer did not ensure that Winder #6 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.  (g) On or about November 20, 2026, the employer did not ensure that Winder #7 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.  (h) On or about November 20, 2026, the employer did not ensure that Winder #8 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.  (i) On or about November 20, 2026, the employer did not ensure that Winder #9 was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.  (j) On or about November 20, 2026, the employer did not ensure that Winder #12 Armature Coil Equipment, Inc. Coil Winder (model no. 3UPAS-II, serial no. W127822-1) was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.  (k) On or about November 20, 2026, the employer did not ensure that Winder #13 Armature Coil Equipment, Inc. Coil Winder (model no. 3UPAS-II, serial no. W127822-2)was provided with adequate guarding to protect employees from injury from the rotating metal frames and wire as the wire was applied creating a nip point where employees hands or clothing could get caught creating an entanglement hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348606203.