OSHA Inspection: FORMTIGHT, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FORMTIGHT, INC. in 11600 E. 51ST AVE., DENVER, CO 80239 (NAICS 326112). OSHA activity number 340107382.

Watch Formtight, INC. — free Get an email when a new federal OSHA severe-injury report for Formtight, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FORMTIGHT, INC.
Site address
11600 E. 51ST AVE.
City
DENVER
State
CO
ZIP
80239
Mailing
11600 E. 51ST AVE., DENVER, CO 80239
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326112
Employees
59
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1750.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a) Formtight, Inc. at 11600 E 51st Ave., Denver, CO 80239:  On or before November 26th, 2014, the employer did not ensure that an energy control program, specific to the establishment, which included energy control procedures, employee training and periodic inspections was established.  This condition exposed employees conducting servicing or maintenance operations to hazards associated with unexpected energizing, startup or release of stored energy.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.147 C04 II C

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.  a) Formtight, Inc. at 11600 E 51st Ave., Denver, CO 80239:  On or before November 26th, 2014, the employer did not ensure that specific steps were developed for the placement, removal and transfer of lockout devices, with designated responsibility for them, in that alternate keys for lockout devices were readily available for any employee to use.  This condition exposed employees to hazards associated with uncontrolled hazardous energy.