Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ROBINSON METAL INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROBINSON METAL INC in 117 S. WASHINGTON ST., GREEN BAY, WI 54301 (NAICS 238220). OSHA activity number 340113505.

Watch Robinson Metal INC — free Get an email when a new federal OSHA severe-injury report for Robinson Metal INC is published. One employer, no account, unsubscribe in one click.
Establishment
ROBINSON METAL INC
Site address
117 S. WASHINGTON ST.
City
GREEN BAY
State
WI
ZIP
54301
Mailing
1740 EISENHOWER DR., DE PERE, WI 54115
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
40
Ownership type
A

4 citations on file for this inspection.

1926.151 A01

Serious Gravity 10 3 instances 25 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $5600.00 Reduced
29 CFR 1926.151(a)(1): Electrical wiring and equipment for light, heat, or power purposes were not installed in compliance with the requirements of 29 CFR 1926, Subpart K:      On and before 12/2/14, two temporary heating units were used on a construction site when the electrical connections did not comply with Subpart K in that one cord was not used as listed or labeled and the plug was not installed correctly and the ground was not continuous.
Recent events (2)
  • — I (S) $5600
  • — Z (S) $7000

1926.403 B02

Serious Gravity 10 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    On and before 12/2/14, a Lennox furnace used for temporary heat was powered by a length of 14/2 w/ground Romex cable which is not listed or labeled for use as a flexible cord for tools and appliances.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 F06

Serious Gravity 10 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:   On and before 12/2/14, the grounding conductor on the 14/2 w/ground Romex cable supplying the temporary heater was missing and not connected to the plug.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 10 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    On and before 12/2/14, the plug attached to the 14/2 w/ground Romex feeding the temporary heater was not installed with the strain relief secured to the cable sheath to prevent tension on the terminal screws.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View ROBINSON METAL INC's full OSHA safety record →