LAVONIA, GA —
OSHA Inspection: RITZ INSTRUMENT TRANSFORMERS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of RITZ INSTRUMENT TRANSFORMERS, INC. in 25 HAMBURG AVE., LAVONIA, GA 30553 (NAICS 334416). OSHA activity number 340136704.
Where did this inspection happen?
- Establishment
- RITZ INSTRUMENT TRANSFORMERS, INC.
- Site address
- 25 HAMBURG AVE.
- City
- LAVONIA
- State
- GA
- ZIP
- 30553
- Mailing
- 25 HAMBURG AVE., LAVONIA, GA 30553
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334416
- Employees
- 77
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $4410.00 · Current $2640.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, and rotating parts: a. On or about December 12, 2014 employees working in the winding department were exposed to caught-in hazards where the employer did not ensure that moving parts of the "Jovil Universal" model SMC-2E, serial number 2009012 winding machine was guarded during operation. b. On or about December 12, 2014 employees working in the winding department were exposed to caught-in hazards where the employer did not ensure that moving parts of the "Guangri electric Machinery" model JG-6204, serial number 00-6204-D822C-6 winding machine was guarded during operation. c. On or about December 12, 2014 employees working in the winding department were exposed to caught-in hazards where the employer did not ensure that moving parts of the "Guangri electric Machinery" model JG-4163, serial number 2000-4163-C92376 winding machine was guarded during operation. d. On or about December 12, 2014 employees working in the winding department were exposed to caught-in hazards where the employer did not ensure that moving parts of the "Guangri electric Machinery" model JG-7204, serial number 7204-7-109-168 winding machine was guarded during operation. e. On or about December 12, 2014 employees working in the winding department were exposed to caught-in hazards where the employer did not ensure that moving parts of the "V & C Standard" model SVE-3, serial number 2030310 winding machine was guarded during operation. f. On or about December 12, 2014 employees working in the winding department were exposed to caught-in hazards where the employer did not ensure that moving parts of the "Guangri electric Machinery" model JG-8204, serial number 8204-4410 winding machine was guarded during operation. g. On or about December 12, 2014 employees working in the winding department were exposed to caught-in hazards where the employer did not ensure that moving parts of the "Guangri electric Machinery" model JG-8204, serial number 8204-0111 winding machine was guarded during operation. h. On or about December 12, 2014 employees working in the winding department were exposed to caught-in hazards where the employer did not ensure that moving parts of the "Guangri electric Machinery" model JG-8554T, serial number 2000-8554-01-6 winding machine was guarded during operation.
Recent events (2)
- — I (S) $2640
- — Z (S) $4410
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $1418.00 · Current $850.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords were used as a substitute for the fixed wiring of a structure. On or about December 12, 2014 adjacent to the low voltage molding department employees were exposed to electrical hazards where the employer used flexible cord as a substitute for fixed wiring to provide power to electric motors used to rotate drums containing Stobicast M 615.02-B and Cridel resin.
Recent events (2)
- — I (S) $850
- — Z (S) $1418
1910.305 G01 IV D
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were used where attached to building surfaces. On or about December 12, 2014 adjacent to the low voltage molding department employees were exposed to electrical hazards where the employer used flexible cord attached to a metal storage rack using cable ties to provide power to electric motors used to rotate drums containing Stobicast M 615.02-B and Cridel resin.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at RITZ INSTRUMENT TRANSFORMERS, INC.
LAVONIA, GA—2013-10-24 00:00:00
RITZ INSTRUMENT TRANSFORMERS, INC
View RITZ INSTRUMENT TRANSFORMERS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334416)
BLAND, VA—2026-03-02
HITACHI ENERGY USA INC.
RINCON, GA—2025-11-21
CARAVELS, LLC
GERMANTOWN, WI—2025-11-20
TCI, LLC.
PALO ALTO, CA—2025-06-25
PEARSON ELECTRONICS INC.
RINCON, GA—2025-06-09
CARAVELS, LLC
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source