SAVANNAH, GA —
OSHA Inspection: POTTER CONSTRUCTION, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of POTTER CONSTRUCTION, LLC in 119 JOHNNY MERCER, SAVANNAH, GA 31410 (NAICS 237110). OSHA activity number 340461300.
Where did this inspection happen?
- Establishment
- POTTER CONSTRUCTION, LLC
- Site address
- 119 JOHNNY MERCER
- City
- SAVANNAH
- State
- GA
- ZIP
- 31410
- Mailing
- 540 SHEAROUSE ROAD, GUYTON, GA 31312
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- Yes
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 20
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) At the site, on or about March 12, 2015 and at times prior to, the employer did not develop or implement a written respiratory protection program for employees who were required to wear 1/2 mask elastomeric respirators while cutting concrete, resulting in a respiratory hazard. Abatement Note: A minimally acceptable respiratory protection program shall include all of the following requirements: 1. Written standard operating procedures governing the selection and use of respirators shall be established. 2. Only approved respirators shall be used. Respirators shall be selected on the basis of hazards to which the worker is exposed. 3. Respirators must be provided free-of-charge where respirators are needed to protect the health of the employees. 4. Employers must provide (free-of-charge) a medical evaluation to determine each employee's fitness to wear a respirator before initial use. 5. Before initial respirator use, fit testing is required for all employees using negative or positive pressure tight-fitting respirators where such respirators are required by OSHA or where the employer requires the use of such a respirator. 6. The user shall be instructed and trained in the proper use of respirators and their limitations. 7. Surveillance of work area conditions and degree of employee exposure or stress shall be conducted. 8. Employer must ensure the use of respirators where respirators are needed to protect the health of the employees. 9. Respirators shall be regularly cleaned and disinfected to keep them in a sanitary condition. 10. Respirators shall be stored in a clean and sanitary location to prevent damage and contamination. 11. Respirators shall be inspected during cleaning and repaired when necessary. 12. There shall be regular inspection and evaluation to determine the continued effectiveness of the program.
Recent events (1)
- — Z (S) $1200
More inspections at POTTER CONSTRUCTION, LLC
BEAUFORT, SC—2016-02-19 00:00:00
POTTER CONSTRUCTION, LLC
SAVANNAH, GA—2015-03-12 00:00:00
POTTER CONSTRUCTION, LLC
View POTTER CONSTRUCTION, LLC's full OSHA safety record →
More inspections in this industry (NAICS 237110)
CHESAPEAKE, VA—2026-07-10
A&W CONTRACTORS, INC.
BRIDGEPORT, CT—2026-07-10
WRR, INC.
MARYSVILLE, WA—2026-07-09
WA317992011 - BDZ DEVELOPERS INC
PEORIA, IL—2026-07-08
WALTERS WATERWORKS LLC DBA MR. ROOTER PLUMBING OF PEORIA
TAMPA, FL—2026-07-08
DALLAS 1 CONSTRUCTION AND DEVELOPMENT, INC.
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340461300.