Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SIGNATURE BUILDING SYSTEMS OF PENNSYLVANIA, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of SIGNATURE BUILDING SYSTEMS OF PENNSYLVANIA, LLC in 1004 SPRINGBROOK AVENUE, MOOSIC, PA 18507 (NAICS 236115). OSHA activity number 340477850.

Watch Signature Building Systems OF Pennsylvania, LLC — free Get an email when a new federal OSHA severe-injury report for Signature Building Systems OF Pennsylvania, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1004 SPRINGBROOK AVENUE
City
MOOSIC
State
PA
ZIP
18507
Mailing
1004 SPRINGBROOK AVENUE, MOOSIC, PA 18507
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
124
Ownership type
A

1 citation on file for this inspection.

1910.95 G08 II A

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $2025.00 Reduced

Hazardous substances 8111

29 CFR 1910.95(g)(8)(ii)(A): Unless a physician determines that the standard threshold shift is not work-related or aggravated by occupational noise exposure, the employer did not ensure, when a standard threshold shift occurs, that employees not using hearing protectors were fitted with hearing protectors, trained in their use and care, and required to use them:  a) Short Wall Dept, an employee with a current diagnosed Standard Threshold Shift (STS) was exposed to noise levels above 85 decibels (dBA), while building short walls and components.  An extrapolated full shift noise level is approximately 65.7% of the allowable 8-hour time weighted sound level of 90 decibels (dBA).  The equivalent dBA level of 65.7% is approximately 87 dBA, and is representative of this employee 's 8-hour time-weighted average.  During high intensity nailing, the average dBA was measured at 94 dBA.  The employer did not ensure that the affected employee wore hearing protection, on or about March 19, 2015.     "ABATEMENT CERTIFICATION REQUIRED"
Recent events (2)
  • — I (S) $2025
  • — Z (S) $2700

View SIGNATURE BUILDING SYSTEMS OF PENNSYLVANIA, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340477850.