Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMERICA CONTRACTORS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMERICA CONTRACTORS, LLC in PRESERVE AT MONTGOMERY LOT 69, GILBERTSVILLE, PA 19525 (NAICS 238170). OSHA activity number 340528033.

Watch America Contractors, LLC — free Get an email when a new federal OSHA severe-injury report for America Contractors, LLC is published. One employer, no account, unsubscribe in one click.
Site address
PRESERVE AT MONTGOMERY LOT 69
City
GILBERTSVILLE
State
PA
ZIP
19525
Mailing
2115 ALDRIN ROAD APT. 6A, OCEAN, NJ 07712
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

8 citations on file for this inspection.

1926.451 C02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement:  a) Preserve at Montgomery, Lot 69, Worksite - on or about April 7, 2015, employees are installing siding from a pump jack scaffold, approximately 21 feet above grade, where the pole ends were not set upon level, rigid, or sound footing.
Recent events (1)
  • — Z (S) $2000

1926.451 F01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(1): Scaffolds and scaffold components shall not be loaded in excess of their maximum intended loads or rated capacities, whichever is less.  a) Preserve at Montgomery, Lot 69, Worksite - on or about April 7, 2015, two employees are installing siding from a pump jack scaffold, approximately 21 feet above grade, while working on a platform which was rated for 250 pounds, but the combined body weight of the two mean exceeded this capacity.
Recent events (1)
  • — Z (S) $0

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  a) Preserve at Montgomery, Lot 69, Worksite - on or about April 7, 2015, employees are installing siding from a pump jack scaffold, approximately 21 feet above grade, where only the pole ends tops were secured by rigid triangular bracing.
Recent events (1)
  • — Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  a) Preserve at Montgomery, Lot 69, Worksite - on or about April 7, 2015, employees are installing siding from a pump jack scaffold, approximately 21 feet above grade, and but did not access the scaffold while at working height by a suitable means of access and egress.
Recent events (1)
  • — Z (S) $2800

1926.1051 A

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:  a) Preserve at Montgomery, Lot 69, Worksite - on or about April 7, 2015, employees are installing siding on a residential home site while using a pump jack scaffold without a dedicated and proper means of access or egress, which requires the workers to transit the roof and lower themselves to the scaffold working platform, approximately 36 inches to the scaffold plank.
Recent events (1)
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  a) Preserve at Montgomery, Lot 69, Worksite - on or about April 7, 2015, employees are installing siding from a pump jack scaffold, approximately 21 feet above grade, and but did not access the scaffold while at working height by a suitable means of access and egress.
Recent events (1)
  • — Z (S) $2800

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):   a) Preserve at Montgomery, Lot 69, Worksite - on or about April 7, 2015, employees are installing siding from a pump jack scaffold, approximately 21 feet above grade, but are conducting additional work or scaffold access via the roof of the new residential project without wearing any means of fall protection.
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) Preserve at Montgomery, Lot 69, Worksite - on or about April 7, 2015, employees are installing siding on a residential home site while using aluminum extension ladder, which did not extend at least three feet above the upper landing surface, nor was provided a grasping device to assist with the transition to the working surface.
Recent events (1)
  • — Z (S) $2000

View AMERICA CONTRACTORS, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340528033.