Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISION ROLL GRINDERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRECISION ROLL GRINDERS, INC. in 6356 CHAPMANS ROAD, ALLENTOWN, PA 18106 (NAICS 332813). OSHA activity number 341221752.

Watch Precision Roll Grinders, INC. — free Get an email when a new federal OSHA severe-injury report for Precision Roll Grinders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6356 CHAPMANS ROAD
City
ALLENTOWN
State
PA
ZIP
18106
Mailing
6356 CHAPMANS ROAD, ALLENTOWN, PA 18106
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
58
Ownership type
A

6 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3825.00 · Current $2678.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) Precision Roll Grinders, Inc. - On or about June 15, 2016, employer did not conduct a periodic inspection of the energy control procedure at least annually.
Recent events (2)
  • — I (S) $2677.5
  • — Z (S) $3825

1910.147 C07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:    a) Precision Roll Grinders, Inc. - On or about June 15, 2016, employees performing set up and maintenance on machines were not provided with adequate training to ensure that the purpose and function of the energy control program was understood.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tag out procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    a) Precision Roll Grinders, Inc. - On or about June 15, 2016, the employers written procedures for lock out tag out was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2066.00 · Current $1446.00 Reduced
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    a) Precision Roll Grinders, Inc. - On or about June 15, 2016 employees permitted to use portable fire extinguishers were not provided with an educational program to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting.
Recent events (2)
  • — I (S) $1446.2
  • — Z (S) $2066

1910.147 C07 IV

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:    a) Precision Roll Grinders, Inc. - On or about June 15, 2016, did not certify that employees were trained in the knowledge and skills required for the safe application, use, and removal of energy controls.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.184 F01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.184(f)(1): Wire-rope slings did not  have permanently affixed and legible identification markings as prescribed by the manufacturer  that indicated the recommended safe working load for the type(s) of hitch(es) used, the angle upon which it is based, and the number of legs if more than one:  a) Precision Roll Grinders, Inc. - On or about June 15, 2016, wire rope slings used to lift a roll device with an overhead crane did not have permanently affixed and legible identification markings as prescribed by the manufacturer.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PRECISION ROLL GRINDERS, INC.'s full OSHA safety record →