PALMERTON, PA —
OSHA Inspection: HORSEHEAD CORPORATION
Monitoring inspection · Health discipline
At a glance
On , OSHA opened a monitoring health inspection of HORSEHEAD CORPORATION in 900 DELAWARE AVENUE, PALMERTON, PA 18071 (NAICS 331492). OSHA activity number 341359511.
Where did this inspection happen?
- Establishment
- HORSEHEAD CORPORATION
- Site address
- 900 DELAWARE AVENUE
- City
- PALMERTON
- State
- PA
- ZIP
- 18071
- Mailing
- 900 DELAWARE AVENUE, PALMERTON, PA 18071
What kind of inspection was it?
- Inspection type
- Monitoring (D)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331492
- Employees
- 118
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 D03 I A
- Issued
- Abate by
- Penalty
- Initial $5610.00 · Current $4208.00 Reduced
1591C141
General-duty citation text
29 CFR 1910.134(d)(3)(i)(A): The employer did not select a respirator that meets or exceeds the required level of employee protection: a) Horsehead Corporation: Employees, Calcine Utility, wore half-mask air-purifying respirators when they were exposed to airborne lead and cadmium at levels that exceeded the respirators assigned protection factor, as discovered on or about 03/29/2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4207.5
- — Z (S) $5610
1910.1025 L01 IV
- Issued
- Penalty
- Initial $2805.00 · Current $2104.00 Reduced
1591
General-duty citation text
29 CFR 1910.1025(l)(1)(iv): A training program was not repeated at least annually for each employee subject to lead exposure at or above the action level, or for whom the possibility of skin or eye irritation existed: a) Horsehead Corporation: An employee, Pelletizer Operator, was exposed to lead above the action level and did not receive lead training within 1 year of his previous lead training, discovered on or about 03/29/2016. b) Horsehead Corporation: An employee, Calcine Utility, was exposed to lead above the action level and did not receive lead training within 1 year of his previous lead training, discovered on or about 03/29/2016. ABATED DURING INSPECTION NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2103.75
- — Z (S) $2805
1910.1027 M04 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
C141
General-duty citation text
29 CFR 1910.1027(m)(4)(ii): Employee information and training were not provided prior to or at the time of initial assignment to a job involving potential exposure to cadmium and at least annually thereafter: a) Horsehead Corporation: An employee, Pelletizer Operator, was exposed to cadmium and did not receive cadmium training within 1 year of his previous cadmium training, discovered on or about 03/29/2016. b) Horsehead Corporation: An employee, Calcine Utility, was exposed to cadmium and did not receive cadmium training within 1 year of his previous cadmium training, discovered on or about 03/29/2016. ABATED DURING INSPECTION NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1027 L02 II B 1
- Issued
- Penalty
- Initial $2805.00 · Current $2104.00 Reduced
C141
General-duty citation text
29 CFR 1910.1027(l)(2)(ii)(B)(1): The initial (preplacement) medical examination did not include biological monitoring that included tests for cadmium in urine (CdU), standardized to grams of creatinine (g/Cr): a) Horsehead Corporation: An employee, Pelletizer Operator, did not receive quantifiable cadmium in urine (CdU) test within 30 days of assignment to job assignment with overexposures to cadmium, as discovered on or about 03/29/2016. ABATED DURING INSPECTION NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2103.75
- — Z (S) $2805
1910.1027 L02 II B 2
- Issued
- Penalty
- Initial $0.00 · Current $0.00
C141
General-duty citation text
29 CFR 1910.1027(l)(2)(ii)(B)(2): The initial (preplacement) medical examination did not include biological monitoring that included beta-2 microglobulin in urine (B2-M), standardized to grams of creatinine (g/Cr), with pH specified as described in Appendix F : a) Horsehead Corporation: An employee, Pelletizer Operator, did not receive quantifiable beta-2 microglobulin in urine (B2-M) test within 30 days of assignment to job assignment with overexposures to cadmium, as discovered on or about 03/29/2016. ABATED DURING INSPECTION NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1027 L04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
C141
General-duty citation text
29 CFR 1910.1027(l)(4)(i): The employer did not provide a periodic medical examination within one year after the initial examination required by 29 CFR 1910.1027(l)(2) and thereafter at least biennially and/or did not provide biological sampling at least annually, either as part of a periodic medical examination or separately as periodic biological monitoring for each employee who was covered under 29 CFR 1910.1027(l)(1): a) Horsehead Corporation: An employee, Pelletizer Operator, did not receive a periodic medical examination for cadmium within one year of his initial examination, as discovered on or about 03/29/2016. b) Horsehead Corporation: An employee, Pelletizer Operator, did not receive a cadmium in urine (CdU) and beta-2-microglobulin in urine [B(2)-M] test within 1 year of his previous biological testing, as discovered on or about 03/29/2016. c) Horsehead Corporation: An employee, Pelletizer Operator, did not receive a quantifiable beta-2-microglobulin in urine [B(2)-M] test within 1 year of his previous biological testing, as discovered on or about 03/29/2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at HORSEHEAD CORPORATION
PALMERTON, PA—2017-04-04 00:00:00
HORSEHEAD CORPORATION
PALMERTON, PA—2016-06-23 00:00:00
HORSEHEAD CORPORATION
CHICAGO, IL—2015-06-15 00:00:00
HORSEHEAD CORPORATION
PALMERTON, PA—2015-05-26 00:00:00
HORSEHEAD CORPORATION
PALMERTON, PA—2014-10-01 00:00:00
HORSEHEAD CORPORATION
View HORSEHEAD CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 331492)
WARWICK, RI—2026-07-16 00:00:00
PEASE & CURREN INCORPORATED
WEST VALLEY CITY, UT—2026-07-08 00:00:00
CASCADE REFINING, INC.
LAWTON, OK—2026-05-18 00:00:00
WESTWIN ELEMENTS, INC.
BEACON FALLS, CT—2026-04-01 00:00:00
KOLGA LLC
NEW HARTFORD, NY—2025-12-18 00:00:00
RESONETICS SMART MATERIALS INC.
More inspections in PA
COLUMBIA, PA—2026-07-17 00:00:00
FOX TAPPING INC.
COLUMBIA, PA—2026-07-17 00:00:00
COLUMBIA WATER CO
WILKES BARRE, PA—2026-07-17 00:00:00
NEW ENTERPRISE STONE & LIME CO., INC.
PHILADELPHIA, PA—2026-07-16 00:00:00
MUKHLEEN GERNAROS PIZZA LLC DBA GENARO'S PIZZERIA AND STEAKS
PHILADELPHIA, PA—2026-07-16 00:00:00
CENTER CITY CONSTRUCTION AND DEVELOPMENT, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341359511.