HARMONY, PA —
OSHA Inspection: AMERICAN MADE, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AMERICAN MADE, LLC in 200 UTAH STREET, HARMONY, PA 16037 (NAICS 325211). OSHA activity number 341596971.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN MADE, LLC
- Site address
- 200 UTAH STREET
- City
- HARMONY
- State
- PA
- ZIP
- 16037
- Mailing
- 200 UTAH STREET, HARMONY, PA 16037
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 101
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.303 B02
- Issued
- Jul 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Facility, Number Seven Laminator: On or before July 5, 2016, employees were exposed to electrical hazards in that a receptacle strip was being used in a manufacturing environment.
Recent events (1)
- — Z (O) $0
1910.303 B07 IV
- Issued
- Jul 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: (a) Facility, Number Seven Laminator: On or before July 5, 2016, employees were exposed to electrical hazards in that a cord was found to have damage near its plug end.
Recent events (1)
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Jul 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Facility, Number Seven Laminator: On or before July 5, 2016, employees were exposed to electrical hazards in that an extension cord was being used in lieu of permanent wiring to power a receptacle strip.
Recent events (1)
- — Z (O) $0
More inspections at American Made, LLC
View American Made, LLC's full OSHA safety record →
More inspections in this industry (NAICS 325211)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341596971.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.