CHILTON, WI —
OSHA Inspection: AMERICAN FINISHING RESOURCES LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AMERICAN FINISHING RESOURCES LLC in 476 CLAY ST., CHILTON, WI 53014 (NAICS 332813). OSHA activity number 342233475.
Where did this inspection happen?
- Establishment
- AMERICAN FINISHING RESOURCES LLC
- Site address
- 476 CLAY ST.
- City
- CHILTON
- State
- WI
- ZIP
- 53014
- Mailing
- PO BOX 164, CHILTON, WI 53014
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 60
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.219 C04 I
- Issued
- Abate by
- Penalty
- Initial $6926.00 · Current $4156.00 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves. a. On or about April 7, 2017, at the facility located at 476 Clay St. Chilton, WI 53014, the employer did not guard the projecting shaft end on the power washer motor for the South side cart washing area.
Recent events (2)
- — I (S) $4155.6
- — Z (S) $6926
1910.219 D01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes. a. On or about April 7, 2017, at the facility located at 476 Clay St. Chilton, WI 53014, the employer did not guard the pulley at the end of the power washer motor for the South side cart washing area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E01 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section. a. On or about April 7, 2017, at the facility located at 476 Clay St. Chilton, WI 53014, the employer did not guard the belt on the power washer motor for the South side cart washing area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01 VI
- Issued
- Abate by
- Penalty
- Initial $6926.00 · Current $4156.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(vi): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees. Arcing effects was not taken into consideration in determining the safety of the equipment. a. On or about April 7, 2017, at the facility located at 476 Clay St. Chilton, WI 53014, the employer was using an electrical outlet that was not free from arcing effects to power a portable fan in the entranceway of the production area.
Recent events (2)
- — I (S) $4155.6
- — Z (S) $6926
1910.305 B01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a. On or about April 7, 2017, at the facility located at 476 Clay St. Chilton, WI 53014, the employer had an electrical switch located on the wall approximately ten feet from the South side power washer motor that was not effectively closed due to an open knock out.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for permanent building wiring. a. On or about April 7, 2017, at the facility located at 476 Clay St. Chilton, WI 53014, the employer used a extension cord as a substitute for permanent building wiring to power a shop light in the entranceway to the production area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at AMERICAN FINISHING RESOURCES LLC
CHILTON, WI—2016-03-29 00:00:00
AMERICAN FINISHING RESOURCES LLC
View AMERICAN FINISHING RESOURCES LLC's full OSHA safety record →
More inspections in this industry (NAICS 332813)
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WICHITA, KS—2026-07-15
PREMIER PROCESSING LLC
WARREN, MI—2026-07-14
AJAX METAL PROCESSING, INC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
WARSAW, IN—2026-07-08
SURFACE ENHANCEMENTS
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source