MANSFIELD, TX —
OSHA Inspection: HOFFMAN CABINETS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HOFFMAN CABINETS, INC. in 204 SENTRY DR., MANSFIELD, TX 76063 (NAICS 337110). OSHA activity number 342561859.
Where did this inspection happen?
- Establishment
- HOFFMAN CABINETS, INC.
- Site address
- 204 SENTRY DR.
- City
- MANSFIELD
- State
- TX
- ZIP
- 76063
- Mailing
- 204 SENTRY DR., MANSFIELD, TX 76063
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 300
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.22 A01
- Issued
- Penalty
- Initial $5541.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms and walking-working surfaces were not kept clean, orderly and in sanitary condition. In the Door Shop, the employer did not ensure that wood dust was cleaned and removed from electrical equipment, machinery, and ledges exposing the employees to fire hazards.
Recent events (2)
- — I (S) $2500
- — Z (S) $5541
1910.134 C
- Issued
- Abate by
- Penalty
- Initial $6519.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: In the Paint Shop, employees were required to wear half-face air purifying respirators and the employer did not develop and implement a written respiratory program exposing employee to respiratory and health hazards.
Recent events (2)
- — I (S) $3000
- — Z (S) $6519
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $6519.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: In the Paint Shop, the employer did not ensure employees required to wear half-face air purifying respirators were provided medical evaluations prior to wear respirators, exposing employees to respiratory and health hazards.
Recent events (2)
- — I (S) $3000
- — Z (S) $6519
1910.134 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): In the Paint Shop, the employer did not ensure employees required to wear half-face air purifying respirators were fit tested and trained prior to allowing employees to wear respirators.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A05
- Issued
- Penalty
- Initial $5541.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: In the Mold Shop, employees used a portable shop fan with the center section of the guard missing exposing the rotating metal blades of the fan. Employees were exposed to laceration and/or amputation hazards.
Recent events (2)
- — I (S) $2500
- — Z (S) $5541
1910.213 D01
- Issued
- Abate by
- Penalty
- Initial $6519.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: In the Specialty Shop, the employer did not ensure the SCM Formula S1 Sliding Table Saw blade was equipped with a guard exposing employees to amputation hazards.
Recent events (2)
- — I (S) $3000
- — Z (S) $6519
1910.213 P04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points: In the Specialty Shop, the employer did not ensure the belt sander pulleys were guarded exposing the employees to caught-in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $6519.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: In the Mold Shop, the employer did not ensure the Mereen-Johnson 312 Rip Saw feeder conveyor chains were guarded exposing employees to caught-in hazards.
Recent events (2)
- — I (S) $3000
- — Z (S) $6519
1910.242 A
- Issued
- Abate by
- Penalty
- Initial $4155.00 · Current $1800.00 Reduced
General-duty citation text
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: In the Door Shop, Specialty Shop and Assembly Production Shops, the employer did not ensure finish nailers were equipped with contact safety tips exposing employees to struck-by injuries.
Recent events (2)
- — I (S) $1800
- — Z (S) $4155
1910.242 B
- Issued
- Penalty
- Initial $4155.00 · Current $1800.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: In the Mold Shop, the employer did not ensure employees used compressed air nozzles that were reduced to 30 P.S.I or less when used for cleaning purposes.
Recent events (2)
- — I (S) $1800
- — Z (S) $4155
1910.303 B02
- Issued
- Penalty
- Initial $4155.00 · Current $1900.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: In the Pocket Hole Section of the Mold Shop, electrical equipment was not used and installed per the listing and labeling and manufacturer guidelines where flexible cord and metal gang outlet boxes were used to power portable equipment exposing employees to electrical shock hazards.
Recent events (2)
- — I (S) $1900
- — Z (S) $4155
1910.304 G05
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: In the Mold Shop, the employer did not ensure shop floor fans cords were equipped with a ground pin exposing employees to electrical shock hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Penalty
- Initial $5541.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: In the Door Shop, the employer did not ensure all circuit breaker and cabinet openings were effectively closed exposing employees to electrical shock injuries.
Recent events (2)
- — I (S) $2500
- — Z (S) $5541
1910.305 G02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: In the Door Shop, the employer did not ensure the Panel Shapers electrical plugs were provided with strain relief exposing employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at HOFFMAN CABINETS, INC.
MANSFIELD, TX—2018-08-22 00:00:00
HOFFMAN CABINETS, INC.
MANSFIELD, TX—2018-08-22 00:00:00
HOFFMAN CABINETS, INC.
View HOFFMAN CABINETS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
VESTAL, NY—2026-07-08
BARNWOOD KITCHEN CABINETS
DEERWOOD, MN—2026-07-02
111522 - DUFFNEY CUSTOM CABINETS LLC
EVERETT, WA—2026-06-29
WA317991850 - JMC CABINETS & INTERIORS INC
PUEBLO, CO—2026-06-26
WESTWIND WOOD SPECIALTIES INC.
BRAINERD, MN—2026-06-25
111484 - TRADITIONAL CABINETRY LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342561859.