Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: NTEX ERECTORS, L.P.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of NTEX ERECTORS, L.P. in 2301 EAST ST. ELMO ROAD, AUSTIN, TX 78744 (NAICS 236220). OSHA activity number 342884095.

Watch Ntex Erectors, L.P. — free Get an email when a new federal OSHA severe-injury report for Ntex Erectors, L.P. is published. One employer, no account, unsubscribe in one click.
Establishment
NTEX ERECTORS, L.P.
Site address
2301 EAST ST. ELMO ROAD
City
AUSTIN
State
TX
ZIP
78744
Mailing
P.O. BOX 174979, ARLINGTON, TX 76003
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
12
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $4000.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of being struck by falling tiltwall:    On or about January 10, 2018, and in times prior thereto, iron workers were lifting tiltwall panels using inserts and clutches from different manufacturers, exposing employees to the hazards to being struck by tiltwall panels in the event of failure.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5174

1926.21 B02

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $3696.00 · Current $2000.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    On or about January 10, 2018, and in times prior thereto, employer did not train employees to make sure the release chains were straightened out down the length of the panel. This created a risk of the release lines and lifting hardware becoming entangled resulting in the release of the clamp unexpectedly.  This condition exposed workers to a hazard of being struck by rigging and concrete tilt-wall panel at the construction site.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $3696

1926.350 B03

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $600.00 Reduced
29 CFR 1926.350(b)(3): Fuel gas cylinder(s) were not placed with the valve end up while in use:    On or about January 10, 2018, and in times prior thereto, oxygen and acetylene cylinders connect for use were mounted in a horizontal position in back of a welding truck exposing iron workers to fire hazard.
Recent events (2)
  • — I (O) $600
  • — Z (S) $2217

1926.704 E

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $2000.00 Reduced
29 CFR 1926.704(e): Employees were permitted under precast concrete members while they were being lifted or tilted into position:    On or about January 10, 2018, and in times prior thereto, workers were not kept clear of tilt-up wall panels being lifted in position.  This condition exposed workers to the hazard of being struck by rigging and concrete panels located at the construction site.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $5174

View NTEX ERECTORS, L.P.'s full OSHA safety record →