SAINT LOUIS, MO —
OSHA Inspection: SHELTON INDUSTRIAL PATTERN INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SHELTON INDUSTRIAL PATTERN INC. in 8925 ZEV AVENUE, SAINT LOUIS, MO 63134 (NAICS 332322). OSHA activity number 342898962.
Where did this inspection happen?
- Establishment
- SHELTON INDUSTRIAL PATTERN INC.
- Site address
- 8925 ZEV AVENUE
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63134
- Mailing
- 8925 ZEV AVENUE, SAINT LOUIS, MO 63134
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 40
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.28 B06 I
- Issued
- Abate by
- Penalty
- Initial $5497.00 · Current $3848.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(6)(i): Each employee less than 4 feet (1.2 m) above dangerous equipment was not protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system: At 8925 Zev Avenue, Berkeley, MO, specifically inside of the Heat Treatment Area, employees were not adequately protected from falling into two pits. The first pit, containing a molten salt bath, measured approximately 77 inches long by 53 inches wide with a 34 inch high coaming along all four sides. The second pit, containing water, measured approximately 92 inches long by 56 inches wide with a 22 inch high coaming along all four sides. The depth of each pit depth was approximately five feet. A travel restraint system was not provided to protect these employees from falling in to either pit. This violation was observed on 01/31/18.
Recent events (2)
- — I (S) $3847.9
- — Z (S) $5497
1910.212 A01
- Issued
- Penalty
- Initial $5497.00 · Current $3848.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: At 8925 Zev Avenue, Berkeley, MO, specifically in the Fabrication Department, the Apex Circular Sander was not adequately guarded. The unguarded portions of this circular sander measured approximately 20 inches in diameter. This violation was observed on 01/31/18. At 8925 Zev Avenue, Berkeley, MO, specifically inside of the Shear Department, the ten stock holders belonging to the Cincinnati Shear, m/n 10-10, s/n 20715, were inadequately guarded. Each stock holder was in front of the finger guard and approximately 3/4" above the shear table. This violation was observed on 01/31/18. At 8925 Zev Avenue, Berkeley, MO, specifically inside of the Forming Department, the rotating parts belonging to a Bosdick Radial Arm Drill were unguarded. This violation was observed on 01/31/18.
Recent events (2)
- — I (S) $3847.9
- — Z (S) $5497
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation (P.O.O.) of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): At 8925 Zev Avenue, Berekley, MO, specifically inside of the Shear Department, the P.O.O. belonging to the Cincinnati Shear, m/n 10-10, s/n 20715, was inadequately guarded. The finger guard was approximately 3/4" above the shear table and 3/4" in front of the blade. This violation was observed on 01/18/18. At 8925 Zev Avenue, Berkeley, MO, specifically inside of the Forming Department, the P.O.O. belonging to the rear of the following machines was unguarded: a/ Drop Hammer #1, 24 X 30. b/ Drop Hammer #2, 36 X 48. c/ Drop Hammer #3, 36 X 48. d/ Drop Hammer #4, 48 X 66. e/ Drop Hammer #5, 60 X 66. f/ Drop Hammer #7, 48 X 48. g/ Drop Hammer #8, 48 X 96. h/ Drop Hammer #9, 24 X 30. i/ Drop Hammer #10, 48 X 48.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at SHELTON INDUSTRIAL PATTERN INC.
BERKELEY, MO—2015-03-12 00:00:00
SHELTON INDUSTRIAL PATTERN , INC
SAINT LOUIS, MO—2013-03-26 00:00:00
SHELTON INDUSTRIAL PATTERN INC.
View SHELTON INDUSTRIAL PATTERN INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
NEW ROCHELLE, NY—2026-07-09
HEFTI HARBOR ELEC FAB & TOOLS
LAKEWOOD, WA—2026-07-08
WA317992020 - KRUEGER SHEET METAL CO
SOUTHAMPTON, MA—2026-07-07
LYMAN SHEET METAL CO., INC
More inspections in MO
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342898962.