2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: NOX US, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NOX US, LLC in 931 SOUTH SPRINGVILLE AVENUE, FOSTORIA, OH 44830 (NAICS 326199). OSHA activity number 342913829.

Watch NOX US, LLC — free Get an email when a new federal OSHA severe-injury report for NOX US, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
NOX US, LLC
Site address
931 SOUTH SPRINGVILLE AVENUE
City
FOSTORIA
State
OH
ZIP
44830
Mailing
931 SOUTH SPRINGVILLE AVENUE, FOSTORIA, OH 44830
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
107
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $9239.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a.)    On or about January 30, 2018, the employer did not ensure energy control procedures were developed, documented, and utilized before performing maintenance tasks on the SILLA die cutter in the offline packing area (Serial #2015-6-170). Employees are required to set the die and are exposed to crush hazards from the cylinders on each side of the open door on the front of the die cutter.
Recent events (3)
  • — F (S) $0
  • — C (S) $9239
  • — Z (S) $9239

1910.147 D03

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):   a.)    On or about January 30, 2018, the employer did not ensure employees were protected while performing maintenance tasks, such as but not limited to changing dies on the SILLA die cutter in the offline packing area (Serial #2015-6-170). Employees are required to set the die and are exposed to crush hazards from the cylinders on each side of the open door on the front of the die cutter.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C07 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $9239.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  On or about January 30, 2018, the employer did not ensure employees were adequately trained in the purpose and function of the energy control program. Employees were required to perform activities such as, changing dies on the SILLA die cutter in the offline packing area (Serial #2015-6-170) and were exposed to crush hazards from accidental startup of the die cutter, in that the equipment was not properly deenergized.
Recent events (3)
  • — F (S) $0
  • — C (S) $9239
  • — Z (S) $9239

View NOX US, LLC's full OSHA safety record →