MILFORD, CT —
OSHA Inspection: NORTHEAST ELECTRONICS, CORP
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of NORTHEAST ELECTRONICS, CORP in 455 BIC DRIVE, MILFORD, CT 06460 (NAICS 334419). OSHA activity number 343081907.
Where did this inspection happen?
- Establishment
- NORTHEAST ELECTRONICS, CORP
- Site address
- 455 BIC DRIVE
- City
- MILFORD
- State
- CT
- ZIP
- 06460
- Mailing
- 455 BIC DRIVE, MILFORD, CT 06460
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334419
- Employees
- 66
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.38 C06
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $3100.00 Reduced
General-duty citation text
29 CFR 1910.38(c)(6): The emergency action plan did not include the name or job title of every employee who may be contacted by employees who need more information about the plan or an explanation of their duties under the plan. Facility: The employer's emergency action plan did not include the names and/or the job titles of staff members who may be contacted by employees, to include temporary workers, for additional information about the plan and/or an explanation of their duties under the plan.
Recent events (2)
- — I (S) $3100
- — Z (S) $3880
1910.38 E
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.38(e): The employer did not designate and train a sufficient number of persons to assist in the safe and orderly emergency evacuation of employees: Facility: A sufficient number of employees were not designated and trained to assist in the safe and orderly emergency evacuation of employees.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.38 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.38(f)(1): The employer did not review the emergency action plan with each employee covered under the plan when the plan was developed or when employees initially were assigned to a job. Facility: The emergency action plan was not reviewed with each employee when it was developed or when employees initially were assigned to the job.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 Q01
- Issued
- Penalty
- Initial $3880.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: Facility: The Toyota powered industrial truck, Model 5FBE20, did not have the emergency brake adjusted properly and was not taken out of service until repairs were made.
Recent events (2)
- — I (S) $0
- — Z (S) $3880
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $3100.00 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided with effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Facility: Each employee required to work around chemicals, such as (but not limited to) the ammonia gas and copper welding fumes was not provided with the information and training on the chemical hazard communications.
Recent events (2)
- — I (S) $3100
- — Z (S) $3880
1910.39 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.39(b): A fire prevention plan was not in writing, kept in the workplace, and was not made available to employees for review. Facility: The employer did not have a written fire prevention plan in place.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at NORTHEAST ELECTRONICS, CORP
Milford, CT—1978-09-26
NORTHEAST ELECTRONICS CORP
Milford, CT—1978-06-20
NORTHEAST ELECTRONICS CORP
View NORTHEAST ELECTRONICS, CORP's full OSHA safety record →
More inspections in this industry (NAICS 334419)
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
GRANTSVILLE, UT—2026-07-13
JABIL, INC.
YORK, PA—2026-06-29
IDSI LLC
COSTA MESA, CA—2026-04-23
MISSION CRITICAL ELECTRONICS
WOBURN, MA—2026-03-31
PARKER HANNIFIN CORPORATION
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source