HIRAM, GA —
OSHA Inspection: METROMONT CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of METROMONT CORPORATION in 200 METROMONT ROAD, HIRAM, GA 30141 (NAICS 327390). OSHA activity number 343141958.
Where did this inspection happen?
- Establishment
- METROMONT CORPORATION
- Site address
- 200 METROMONT ROAD
- City
- HIRAM
- State
- GA
- ZIP
- 30141
- Mailing
- 200 METROMONT ROAD, HIRAM, GA 30141
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 283
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.303 G02 I A
- Issued
- Oct 10, 2018
- Penalty
- Initial $4,005 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i)(A): By location in a room, vault, or similar enclosure that is accessible only to qualified persons; a) Batch Plant Area- On or before April 11, 2018, and at times prior, the employer exposed employees to shock hazards, in that the employer did not ensure that three electrical switch panels were fully closed and locked.
Recent events (2)
- — I (S) $0
- — Z (S) $4005
1910.304 F01 IV
- Issued
- Oct 10, 2018
- Abate by
- Oct 22, 2018
- Penalty
- Initial $4,712 · Current $4,359 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Over-current devices were not readily accessible to each employee or authorized building management personnel. a) Welding Shop Area- On or before April 11, 2018, and at times prior, the employer exposed employees to shock hazards, in that the employer did not ensure that electrical panels and shut down switches were not blocked as required. Boxes were placed approximately 12" in front of electrical panel and electrical shut off.
Recent events (2)
- — I (S) $4359
- — Z (S) $4712
1910.101 B
- Issued
- Oct 10, 2018
- Abate by
- Oct 22, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gasses in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks was not in accordance with Compressed Gas Association Pamphlet P-1-1965: a) Cylinder Storage Area- On or before April 11, 2018, and at times prior, the employer exposed employees to struck-by hazards, in that the employer did not ensure that an Acetylene storage cylinders was chained and stored in an upright position as required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at METROMONT CORPORATION
HIRAM, GA—2026-04-15 00:00:00
METROMONT CORPORATION
SOCIAL CIRCLE, GA—2021-10-19 00:00:00
METROMONT CORPORATION
SOCIAL CIRCLE, GA—2020-08-26 00:00:00
METROMONT CORPORATION
HIRAM, GA—2020-03-19 00:00:00
METROMONT CORPORATION
BARTOW, FL—2019-06-19 00:00:00
METROMONT CORPORATION
View METROMONT CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 327390)
FLANDERS, NJ—2026-07-15 00:00:00
TRI-STATE QUIKRETE
KISSIMMEE, FL—2026-07-15 00:00:00
LAN SE, LLC
FRANKLINTON, NC—2026-07-15 00:00:00
161551 - LINDSAY PRECAST, LLC
GREAT BARRINGTON, MA—2026-07-13 00:00:00
VAULT GALLERY
OGDEN, UT—2026-07-10 00:00:00
OLDCASTLE INFRASTRUCTURE, INC.
More inspections in GA
CHAMBLEE, GA—2026-07-16 00:00:00
U.S. DEPARTMENT OF TREASURY
LAWRENCEVILLE, GA—2026-07-16 00:00:00
REHRIG PACIFIC COMPANY
GREENSBORO, GA—2026-07-16 00:00:00
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16 00:00:00
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16 00:00:00
GF CASTING SOLUTIONS AUGUSTA, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343141958.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.