1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: JOHNSON & JOHNSON CONSUMER, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of JOHNSON & JOHNSON CONSUMER, INC. in 7050 CAMP HILL ROAD, FORT WASHINGTON, PA 19034 (NAICS 325412). OSHA activity number 343279915.

Watch Johnson & Johnson Consumer, INC. — free Get an email when a new federal OSHA severe-injury report for Johnson & Johnson Consumer, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7050 CAMP HILL ROAD
City
FORT WASHINGTON
State
PA
ZIP
19034
Mailing
7050 CAMP HILL ROAD, FORT WASHINGTON, PA 19034
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325412
Employees
1200
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $7853.00 · Current $7853.00
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards such as, but not limited to, chemical burns, burns from flame, and/or struck-by hazards:    a) Quality Assurance Laboratory: On July 3, 2018, waste hydrochloric acid was combined with a mixture of alcohols, potassium hydroxide, and other non-halogenated wastes in the same 5 gallon JustRite waste container.  A rapid over-pressurization occurred in the waste container, which resulted in the lid and flame arrestor being ruptured causing a brief fire.  Although it appears that the over-pressurization may have been casued by the mixing of incompatible chemicals, it has not been conclusively determined that the mixing of incompatible chemicals was the causal factor in the incident.      Feasible means of abatement would include, but are not limited to: logging all chemicals placed into the containers, avoid mixing liquid waste materials in common containers unless determined to be safe through analysis, training workers to be aware of reactivity hazards and incompatibilities, clearly identifying and labeling all reactive materials including what conditions/interactions must be avoided, segregating and separating incompatible materials using dedicated equipment, following the guidelines and specifics codes & standards associated with specific hazard categories of reactive materials (i.e. peroxides, oxidizers, peroxide formers, pyrophoric materials, polymerizing materials, and unstable materials). Possible resources include, but are not limited to, manufacturers safety data sheets, technical bulletins, etc.; the American Institute of Chemical Engineers - Center for Chemical Process Safety; EPA; OSHA; the Chemical Safety and Hazard Investigation Board. the National Fire Protection Association's (NFPA) Hazardous Chemicals Data Compilation (NFPA 49), as contained in NFPA's Fire Protection Guide to Hazardous Materials (2010); NFPA's Compilations of Hazardous Chemical Reactions (NFPA 491) as contained in NFPA's Fire Protection Guide to Hazardous Materials (2010); U.S. National Oceanic and Atmospheric Administration's (NOAA) Chemical Reactivity Worksheet.
Recent events (3)
  • — F (S) $7853
  • — C (S) $7853
  • — Z (S) $7853

1910.106 E06 I

Deleted Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as but not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:  a) Quality Assurance Laboratory: On or about July 3, 2018, an employee added 0.5N alcoholic potassium hydroxide and 0.5N hydrochloric acid to a flammable liquid in a JustRite Safety Can causing an explosion and severely injuring the employee. The facility did not take adequate precautions to prevent static electricity from igniting the flammable vapors.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.