Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PRECISION STAMPING PRODUCTS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRECISION STAMPING PRODUCTS, INC. in 4848 NORTH RIVER ROAD, SCHILLER PARK, IL 60176 (NAICS 332116). OSHA activity number 343336004.

Watch Precision Stamping Products, INC. — free Get an email when a new federal OSHA severe-injury report for Precision Stamping Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4848 NORTH RIVER ROAD
City
SCHILLER PARK
State
IL
ZIP
60176
Mailing
4848 NORTH RIVER ROAD, SCHILLER PARK, IL 60176
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
20
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $5174.00 · Current $3000.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    a) Production Area - On or about July 19, 2018, the employer did not ensure employees performing the task of adjusting and aligning the piece of roll fed material, fed from the Sesco Feeder, model #12-1015, serial #19871, were trained as an authorized employees to acquire the knowledge and skills needed for the safe application, usage, and removal of the energy controls.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5174

1910.147 D

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d): 29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) covered the following elements, however, the actions were not done in sequence as required by 29 CFR 1910.147 (d)(1)-(6):  a) Production Area - On or about July 19, 2018, an employee was exposed to machine hazards associated with moving parts while aligning the piece of roll fed material from the Sesco Feeder, model #12-1015, serial #19871.  The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)], and verification of isolation [(d)(6)], were not implemented to protect the employee from machine servicing hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View PRECISION STAMPING PRODUCTS, INC.'s full OSHA safety record →