1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SHELTER ENTERPRISES INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SHELTER ENTERPRISES INC. in 8 SARATOGA ST., COHOES, NY 12047 (NAICS 326150). OSHA activity number 343769865.

Watch Shelter Enterprises INC. — free Get an email when a new federal OSHA severe-injury report for Shelter Enterprises INC. is published. One employer, no account, unsubscribe in one click.
Site address
8 SARATOGA ST.
City
COHOES
State
NY
ZIP
12047
Mailing
8 SARATOGA ST., COHOES, NY 12047
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326150
Employees
45
Ownership type
A

4 citations on file for this inspection.

1910.28 B01 I A

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $3381.00 · Current $2250.00 Reduced
29 CFR 1910.28(b)(1)(i)(A): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling by a standard guardrail system.    a) Second floor corner near stairs - On February 8, 2019 and at times prior, an opening to the lower floor was only protected by a top guard rail.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3381

1910.216 B01

Serious Gravity 1 1 instance 15 exposed
Issued
Penalty
Initial $3978.00 · Current $2250.00 Reduced
29 CFR 1910.216(b)(1): An accessible safety trip control that operated on contact was not provided in front and/or back of each mill:    a) 1st Floor Grinder Room - On February 8, 2019 and at times prior, the foam grinder had a safety wire around the hopper opening that was inoperative.    Note:  The safety trip control shall be one of the types or a combination thereof as listed in 1910.216(b)(1).
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3978

1910.303 F02

Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a) 2nd Floor Near Cutting Machine - On February 8, 2019, and at times prior, the disconnect switch that controlled the power for the cutting machine was not labeled for purpose/equipment it controlled.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 A02 IV B

Other-than-serious 1 instance 15 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(a)(2)(iv)(B): Conductors were not run as multiconductor cord or cable assemblies; or installed as permitted in paragraph (a)(2)(i)(C) of this section, and were accessible to unqualified persons:  a) 2nd Floor Foam Storage Area - On February 8, 2019, and at times prior, open wiring was installed between a junction box and two disconnect switches without any conduit or protective shielding.  This exposes the energized cables to damage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View SHELTER ENTERPRISES INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343769865.