Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMERICAN EVERGREEN, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERICAN EVERGREEN, INC in SCHOOL STREET AND ROUTE 40, SCHAGHTICOKE, NY 12154 (NAICS 237110). OSHA activity number 344397252.

Watch American Evergreen, INC — free Get an email when a new federal OSHA severe-injury report for American Evergreen, INC is published. One employer, no account, unsubscribe in one click.
Site address
SCHOOL STREET AND ROUTE 40
City
SCHAGHTICOKE
State
NY
ZIP
12154
Mailing
PO BOX 126, WYNANTSKILL, NY 12198
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.651 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3789.00 · Current $2273.00 Reduced
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation.    (a)  At the jobsite, during water main installation:  On or prior to 10/23/19, employees were working in an unprotected trench with visible water accumulation while attempting to tighten fittings on a leaking water main.
Recent events (2)
  • — I (S) $2273.4
  • — Z (S) $3789

1926.652 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3789.00 · Current $2273.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).    (a)  At the jobsite, during water main installation:  On or prior to 10/23/19, employees were working in an unprotected trench which was approximately 7' deep while attempting to tighten fittings on a leaking water main.
Recent events (2)
  • — I (S) $2273.4
  • — Z (S) $3789

1926.1053 B16

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired.  (a)  At the jobsite, during water main installation:  On or prior to 10/23/19, ladder used for egress to/from the excavation was in use with damaged side rails.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View AMERICAN EVERGREEN, INC's full OSHA safety record →