HORICON, WI —
OSHA Inspection: DEERE & COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DEERE & COMPANY in 1501 W. LAKE STREET, HORICON, WI 53032 (NAICS 333111). OSHA activity number 344636006.
Where did this inspection happen?
- Establishment
- DEERE & COMPANY
- Site address
- 1501 W. LAKE STREET
- City
- HORICON
- State
- WI
- ZIP
- 53032
- Mailing
- 300 N. VINE STREET, HORICON, WI 53032
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333111
- Employees
- 1400
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C06 I B
- Issued
- Penalty
- Initial $9831.00 · Current $6883.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(B) The periodic inspection shall be conducted to correct any deviations or inadequacies identified. On or about February 10, 2020, lockout/tagout procedures for the Bond Robotics destacker (Asset No. 6307) were not utilized for the control of the hazardous energy sources when employees entered the operating envelope of the machine to adjust the Syron sensor.
Recent events (3)
- — F (S) $6882.5
- — C (S) $9831
- — Z (S) $9831
1910.147 D02
- Issued
- Penalty
- Initial $9831.00 · Current $6883.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: On or about February 10, 2020, the Bond Robotics destacker (Asset No. 6307) was not shut down using the lockout/tagout procedure for this machine prior to employees making Syron sensor adjustments.
Recent events (3)
- — F (S) $6882.5
- — C (S) $9831
- — Z (S) $9831
1910.147 D03
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about February 10, 2020 all energy isolating devices needed to control energy to the Bond Robotics destacker (Asset No. 6307) were not operated in such a manner as to isolate the destacker from energy sources prior to making Syron sensor adjustments.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about February 10, 2020, lockout or tagout devices were not affixed to each energy isolating device on the Bond Robotics destacker (Asset No. 6307) prior to making adjustments to the Syron sensor.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at DEERE & COMPANY
MILAN, IL—2023-10-25 00:00:00
DEERE & COMPANY
MIAMI, FL—2022-12-15 00:00:00
DEERE & COMPANY
EAST MOLINE, IL—2022-04-14 00:00:00
DEERE & COMPANY
EAST MOLINE, IL—2021-05-25 00:00:00
DEERE & COMPANY
HORICON, WI—2020-01-29 00:00:00
DEERE & COMPANY
View DEERE & COMPANY's full OSHA safety record →
More inspections in this industry (NAICS 333111)
DONALSONVILLE, GA—2026-07-14
LEWIS M. CARTER MANUFACTURING COMPANY, INC.
MARATHON, NY—2026-07-14
AUTOMATED BIOMASS SYSTEMS LLC
EPHRATA, PA—2026-06-12
BLUE RIDGE SILO LLC
NORWOOD YOUNG AMERICA, MN—2026-06-09
111380 - PVS SACKETT-WACONIA INC
FARIBAULT, MN—2026-05-28
111336 - ENVIRONMENTAL TILLAGE SYSTEMS INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344636006.