ARCHBALD, PA —
OSHA Inspection: SIMONA AMERICA INDUSTRIES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SIMONA AMERICA INDUSTRIES in 101 POWER BLVD, ARCHBALD, PA 18403 (NAICS 326113). OSHA activity number 344854096.
Where did this inspection happen?
- Establishment
- SIMONA AMERICA INDUSTRIES
- Site address
- 101 POWER BLVD
- City
- ARCHBALD
- State
- PA
- ZIP
- 18403
- Mailing
- 101 POWER BLVD, ARCHBALD, PA 18403
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326113
- Employees
- 123
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $5205.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Sheet Line #5: Procedures were not utilized for the control of potentially hazardous energy when an employee was engaged in cleaning out the cabinet of the Northtech up saw and received a severe hand injury due to kinetic energy of the saw blade, on or about July 23, 2020. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $5205
1910.147 C04 II B
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: a) Sheet Line #5: The energy control procedures had not been updated to specifically outline the steps for shutting down and securing the new Northtech up cut saw to control hazardous energy, on or about July 28, 2020. Abatement Observed During Inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $3123.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Sheet Line #5: The employer did not conduct a periodic inspection of the energy control procedures at least annually for equipment including, but not limited to, up cut saws to ensure that the procedures and the requirements of this standard were being followed, on or about July 28, 2020. Abatement Certification Required.
Recent events (2)
- — I (S) $3123
- — Z (S) $0
More inspections at SIMONA AMERICA INDUSTRIES
ARCHBALD, PA—2022-11-04 00:00:00
SIMONA AMERICA INDUSTRIES
View SIMONA AMERICA INDUSTRIES's full OSHA safety record →
More inspections in this industry (NAICS 326113)
NARRAGANSETT, RI—2026-07-09
ROGERS CORPORATION
RURAL RETREAT, VA—2026-07-07
KLOCKNER PENTAPLAST OF AMERICA, INC.
SUTTON, MA—2026-07-01
POLYVINYL FILMS, INC.
GARFIELD, NJ—2026-05-22
PRIMEX PLASTICS CORPORATION
FERNLEY, NV—2026-05-21
AGRU AMERICA, INC.
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344854096.