Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HOMEWORKS ENERGY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HOMEWORKS ENERGY, INC. in 357 COTTAGE STREET UNIT 3, SPRINGFIELD, MA 01104 (NAICS 238310). OSHA activity number 345190219.

Watch Homeworks Energy, INC. — free Get an email when a new federal OSHA severe-injury report for Homeworks Energy, INC. is published. One employer, no account, unsubscribe in one click.
Site address
357 COTTAGE STREET UNIT 3
City
SPRINGFIELD
State
MA
ZIP
01104
Mailing
101 STATION LANDING SUITE 110, MEDFORD, MA 02153
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
21
Ownership type
A

6 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $4973.00 · Current $2486.00 Reduced
29 CFR  1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit."  a) 357 Cottage Street, Unit 3, Springfield, MA: On or about March 11, 2021 and at times prior the rear exit door was not marked by a sign reading "Exit".
Recent events (2)
  • — I (S) $2486
  • — Z (S) $4973

1910.134 C01

Serious Gravity 1 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $4973.00 · Current $2487.00 Reduced
29 CFR  1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer did not establish and implement a written respiratory protection program with worksite-specific procedures.    a) 357 Cottage Street, Unit 3, Springfield, MA: On or about March 11, 2021 and at times prior the employer required employees to wear half face elastomeric respirators while working in job-site attics for protection against insulation dust and other hazards for protection and the employer had not developed and implemented a written respirator program.
Recent events (2)
  • — I (S) $2487
  • — Z (S) $4973

1910.134 E01

Serious Gravity 1 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   a) 357 Cottage Street, Unit 3, Springfield, MA: On or about March 11, 2021 and at times prior employees were not medically evaluated for use of respirators.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K

Serious Gravity 5 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:    a) 357 Cottage Street, Unit 3, Springfield, MA: On or about March 11, 2021 and at times  prior employees using half face elastomeric respirators were not fit tested for respirators prior to for use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Deleted Serious Gravity 5 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator.    a) 357 Cottage Street, Unit 3, Springfield, MA: On or about March 11, 2021 and at times prior employees were not fit tested prior to wearing elastomeric half face respirators.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.159 C10

Other-than-serious Gravity 1 1 instance 21 exposed
Issued
Abate by
Penalty
Initial $4973.00 · Current $0.00 Reduced
29 CFR  1910.159(c)(10): The minimum vertical clearance of 18 inches between automatic sprinkler systems sprinklers and the material below was not maintained.   a) 357 Cottage Street, Unit 3, Springfield, MA: On or about March 11, 2021 and at times prior the minimum vertical clearance between sprinklers and materials below in the rear storage room was less than 18 inches (45.7 cm).
Recent events (2)
  • — I (O) $0
  • — Z (S) $4973

View HOMEWORKS ENERGY, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345190219.