1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: WISCONSIN WHEY PROTEIN INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WISCONSIN WHEY PROTEIN INC. in 160 CHRISTENSEN DRIVE, DARLINGTON, WI 53530 (NAICS 311513). OSHA activity number 345415418.

Watch Wisconsin Whey Protein INC. — free Get an email when a new federal OSHA severe-injury report for Wisconsin Whey Protein INC. is published. One employer, no account, unsubscribe in one click.
Site address
160 CHRISTENSEN DRIVE
City
DARLINGTON
State
WI
ZIP
53530
Mailing
160 CHRISTENSEN DRIVE, DARLINGTON, WI 53530
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311513
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8778.00 · Current $4352.00 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:(a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)(IDENTIFY MACHINERY OR EQUIPMENT)(THIS INCLUDES ENFORCEMENT OF PROCEDURES)
Recent events (2)
  • — I (S) $4352
  • — Z (S) $8778

1910.147 C01

Other-than-serious 1 instance 16 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  On or about July 13, 2021, the employer had not established an energy control (lockout/tagout) program to ensure that employees performing CIP and other servicing and/or maintenance activities would correctly shut down and isolate the energy sources for equipment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View WISCONSIN WHEY PROTEIN INC.'s full OSHA safety record →