LOVELAND, OH —
OSHA Inspection: CHIMNEY WORKS & ROCKY MOUNTAIN STOVES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHIMNEY WORKS & ROCKY MOUNTAIN STOVES in 507 BRANCH HILL-LOVELAND ROAD, LOVELAND, OH 45140 (NAICS 238140). OSHA activity number 345647564.
Where did this inspection happen?
- Establishment
- CHIMNEY WORKS & ROCKY MOUNTAIN STOVES
- Site address
- 507 BRANCH HILL-LOVELAND ROAD
- City
- LOVELAND
- State
- OH
- ZIP
- 45140
- Mailing
- 2450 CIVIC CENTER DRIVE, CINCINNATI, OH 45231
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 40
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B03
- Issued
- Penalty
- Initial $10151.00 · Current $6091.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(3): General requirements. Scaffold platform construction. Except as provided in paragraphs (b)(3)(i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling. a) On or about November 16, 2021, employees were utilizing a scaffold system with a front edge platform distance of 2 ft. from the working area; without a guardrail system and a proper fall protection system in place.
Recent events (2)
- — I (S) $6090.6
- — Z (S) $10151
1926.451 E06 I
- Issued
- Penalty
- Initial $10151.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(6)(i): General requirements. Access. Integral prefabricated scaffold access frames shall: Be specifically designed and constructed for use as ladder rungs. a) On or about November 16, 2021, employees were utilizing an in-frame side ladder to access a tubular welded-frame scaffold system, measured at a height of approximately 26 ft. from a wooded deck area. Such in-frame ladder was not specifically designed for use as ladder rungs.
Recent events (2)
- — I (S) $0
- — Z (S) $10151
1926.451 F07
- Issued
- Penalty
- Initial $10151.00 · Current $6091.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): General requirements. Use. Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person. a) On or about November 16, 2021, employees were working on repairs of a chimney, a crew leader in charge at the job-site, erected the scaffold system upon arriving at the job-site. However, there was no competent person present at the job-site on this day during the time that the scaffold systems was being erected.
Recent events (2)
- — I (S) $6090.6
- — Z (S) $10151
1926.451 G03 IV
- Issued
- Penalty
- Initial $10151.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(3)(iv): General requirements. Fall protection. Vertical lifelines, independent support lines, and suspension ropes shall not be attached to each other, nor shall they be attached to or use the same point of anchorage, nor shall they be attached to the same point on the scaffold or personal fall arrest system. a) On or about November 16, 2021, an employee while working on the top tier of a tubular welded-frame scaffold was exposed to a fall hazard measured approximately 26 ft. from a wooded deck. The employee was utilizing two 2 ft. lanyards attached to each other and these lanyards were anchored in the top tier of the tubular welded-frame scaffold as fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $10151
1926.454 C03
- Issued
- Abate by
- Penalty
- Initial $10151.00 · Current $6091.00 Reduced
General-duty citation text
29 CFR 1926.454(c)(3): Training requirements. When the employer has reason to believe: Where inadequacies in an affected employee's work involving scaffolds indicate that the employee has not retained the requisite proficiency. a) On or about November 16, 2021 each employee working from the tubular welded-frame scaffold that have been previously trained on fall protection and the use of scaffolds did not retained the requisite proficiency and procedures to recognize and minimized hazards situations while erecting and using a tubular welded-frame scaffold erected over 20 feet.
Recent events (2)
- — I (S) $6090.6
- — Z (S) $10151
More inspections at CHIMNEY WORKS & ROCKY MOUNTAIN STOVES
CINCINNATI, OH—2021-04-21 00:00:00
CHIMNEY WORKS & ROCKY MOUNTAIN STOVES
View CHIMNEY WORKS & ROCKY MOUNTAIN STOVES's full OSHA safety record →
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345647564.