DENISON, TX —
OSHA Inspection: CHAMPION COOLER
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CHAMPION COOLER in 3328 INTERURBAN RD., DENISON, TX 75020 (NAICS 333415). OSHA activity number 346358906.
Where did this inspection happen?
- Establishment
- CHAMPION COOLER
- Site address
- 3328 INTERURBAN RD.
- City
- DENISON
- State
- TX
- ZIP
- 75020
- Mailing
- 3328 INTERURBAN RD., DENISON, TX 75020
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 160
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.253 B02 II
- Issued
- Penalty
- Initial $6026.00 · Current $3616.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: On or about November 10, 2022 and at dates prior thereto for employees exposed to fire and struck-by hazards where an acetylene cylinder was not secured or stored to prevent being knocked over.
Recent events (2)
- — I (S) $3615.6
- — Z (S) $6026
1910.253 B02 IV
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(2)(iv):Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: On or about November 10, 2022 and at dates prior thereto for employees exposed to fire and struck-by hazards where an acetylene cylinder was placed into storage without it's valve cap in place.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.252 C06 II
- Issued
- Penalty
- Initial $12053.00 · Current $7232.00 Reduced
2610
General-duty citation text
29 CFR 1910.252(c)(6)(ii):Indoor welding or cutting involving zinc-bearing base or filler metals coated with zinc-bearing materials was not done in accordance with 29 CFR 1910.252(c)(3): On or about November 10, 2022, and at dates prior thereto, for employees exposed to respiratory hazards from zinc oxide fumes while welding galvanized steel, where the employer did not provide a compliant exhaust ventilation system. NOTE: Champion Cooler was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.252(c)(6)(ii) which was contained in OSHA inspection number 1603077, citation number 1, item number 1 and was affirmed as a final order on September 6, 2022, with respect to a workplace located at 1724 South Scullin Avenue, Denison, Texas.
Recent events (2)
- — I (R) $7231.8
- — Z (R) $12053
More inspections at CHAMPION COOLER
DENISON, TX—2019-05-21 00:00:00
CHAMPION COOLER
View CHAMPION COOLER's full OSHA safety record →
More inspections in this industry (NAICS 333415)
LAUREL, MS—2026-07-01
THERMO-KOOL
OSSEO, WI—2026-07-01
TITAN AIR, LLLP
OSSEO, WI—2026-06-22
TITAN AIR, LLLP
LA CROSSE, WI—2026-05-28
TRANE U.S. INC.
COLONIAL HEIGHTS, VA—2026-05-26
HILL PHOENIX, INC.
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source