1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: WILLMAN INDUSTRIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WILLMAN INDUSTRIES, INC. in 338 S. MAIN ST., CEDAR GROVE, WI 53013 (NAICS 331511). OSHA activity number 346363369.

Watch Willman Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Willman Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
338 S. MAIN ST.
City
CEDAR GROVE
State
WI
ZIP
53013
Mailing
338 S. MAIN ST., CEDAR GROVE, WI 53013
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
133
Ownership type
A

2 citations on file for this inspection.

1910.184 C01

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $6026.00 · Current $3013.00 Reduced
29 CFR 1910.184(c)(1): Slings that are damaged or defective shall not be used.  On or about November 11, 2022, at the facility located at 338 South Main Street, Cedar Grove Wisconsin; the employer failed to ensure that altered or defective slings were not used.  Employees used a three-leg alloy steel chain sling with a master ring that was engraved with "Kuplex T/V" and "K-2 G8/G10" on the other side.  The sling had three hooks with "SN28266" engraved on the sling.  The "J" portion of the hooks were ground down to make a pins.
Recent events (2)
  • — I (O) $3013
  • — Z (S) $6026

1910.184 E01

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.184(e)(1): Sling identification. Alloy steel chain slings shall have permanently affixed durable identification stating size, grade, rated capacity, and reach.  On or about November 11, 2022, at the facility located at 338 South Main Street, Cedar Grove Wisconsin; the employer failed to ensure that alloy steel slings used in the workplace contained permanently affixed identification stating size, grade, rated capacity, and reach.  Employees used a three-leg alloy steel chain sling with a master ring is engraved with "Kuplex T/V" and "K-2 G8/G10" on the other side.  The sling did not have a permanently affixed identification.