BORGER, TX —
OSHA Inspection: TOKAI CARBON CB, LTD.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TOKAI CARBON CB, LTD. in 9455 FARM TO MARKET ROAD 1559, BORGER, TX 79007 (NAICS 335991). OSHA activity number 346556806.
Where did this inspection happen?
- Establishment
- TOKAI CARBON CB, LTD.
- Site address
- 9455 FARM TO MARKET ROAD 1559
- City
- BORGER
- State
- TX
- ZIP
- 79007
- Mailing
- 201 MAIN STREET, STE 3000, FORT WORTH, TX 76102
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335991
- Employees
- 179
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.22 A03
- Issued
- Abate by
- Penalty
- Initial $12055.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice. On or about March 9, 2023, the employer did not ensure safe walking working surfaces in the listed below areas, but not limited to, due to corrosion exposing employees to struck-by, fall and trip hazards. a. Employer did not provide a safe walking working surfaces in the wet pallet area adjacent westside stairs, in plant 1, due to a support beam for the floor having the webbing rusted completely out due to corrosion. b. Employer did not provide a safe walking working surfaces in the leveling screw area adjacent westside stairs, in plant 1, where a hole in the floor, in the front of the leveling screw machine, caused by corrosion of the metal exposed employees to trip hazards. c. Employer did not provide a safe walking working surfaces in the PO2 Spoon area, in plant 2, due to holes in the grating of the walking working surfaces exposing employees to trip hazards due to the corrosion. d. Employer did not provide a safe walking working surfaces in the conveyor area, in plant 2, due to a hole in the walking working surfaces caused by the corrosion, exposing employees to trip hazards. e. Employer did not provided a safe walking working surfaces in the C32 area, in plant 2, where is a hole in the walking working surface, exposing employees to trip hazards due to the corrosion. The grating and the support for the grating was corroded and part of the grating had separated due to the corrosion.
Recent events (2)
- — I (S) $0
- — Z (S) $12055
1910.22 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $7233.00
General-duty citation text
29 CFR 1910.22(b): The employer did not ensure that each walking-working surface can support the maximum intended load for that surface. On or about March 9, 2023, the employer did not demonstrate that structures were safe as walking working surfaces due to corrosion, exposing employees to struck by, fall and trip hazards in the following areas, but not limited to these instances: a. Employer did not provide a safe walking working surfaces in the wet pallet area adjacent westside stairs, in plant 1, due to a support beam for the floor having the webbing rusted completely out due to corrosion. b. Employer did not provide a safe walking working surfaces in the leveling screw area adjacent westside stairs, in plant 1, where a hole in the floor, in the front of the leveling screw machine, caused by corrosion of the metal exposed employees to trip hazards. c. Employer did not provide a safe walking working surfaces in the PO2 Spoon area, in plant 2, due to holes in the grating of the walking working surfaces exposing employees to trip hazards due to the corrosion. d. Employer did not provide a safe walking working surfaces in the conveyor area, in plant 2, due to a hole in the walking working surfaces caused by the corrosion, exposing employees to trip hazards. e. Employer did not provided a safe walking working surfaces in the C32 area, in plant 2, where is a hole in the walking working surface, exposing employees to trip hazards due to the corrosion. The grating and the support for the grating was corroded and part of the grating had separated due to the corrosion. f. The employer did not ensure that stairs near the twilight tank area, in plant 2 can support anticipated live load exposing employees to trip hazards due to the corrosion and holes in the stairs walking working surface. g. The employer did not ensure that stairs near the weigh tank, in plant 2 can support anticipated live load exposing employees to trip hazards due to the corrosion and holes in the stairs walking working surface.
Recent events (2)
- — I (S) $7233
- — Z (S) $0
1910.22 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(d)(2): The employer did not ensure that hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface again. The employer did not ensure that if the correction or repair cannot be made immediately, the hazard is guarded to prevent employees from using the walking-working surface until the hazard is corrected or repaired. On or about March 9, 2023 the employer did not ensure that hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface again, in different areas, but not limited to the following instances due to corrosion exposing employees to struck by, fall and trip hazards. a. Employer did not ensure that hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface again, in the wet pallet area adjacent westside stairs, in plant 1, due to a support beam for the floor having the webbing rusted completely out due to corrosion. b. Employer did not ensure that hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface again, in the leveling screw area adjacent westside stairs, in plant 1, where a hole in the floor, in the front of the leveling screw machine, caused by corrosion of the metal exposed employees to trip hazards. c. Employer did not ensure that hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface again, in the PO2 Spoon area, in plant 2, due to holes in the grating of the walking working surfaces exposing employees to trip hazards due to the corrosion. d. Employer did not ensure that hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface again in the conveyor area, in plant 2, due to a hole in the walking working surfaces caused by the corrosion, exposing employees to trip hazards. e. Employer did not ensure that hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface again, in the C32 area, in plant 2, where is a hole in the walking working surface, exposing employees to trip hazards due to the corrosion. The grating and the support for the grating was corroded and part of the grating had separated due to the corrosion.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.25 B03
- Issued
- Abate by
- Penalty
- Initial $6026.00 · Current $3616.00 Reduced
General-duty citation text
29 CFR 1910.25(b)(3): The employer must ensure stairs have uniform riser heights and tread depths between landings. On or about August 29, 2023, the employer did not ensure stairs had uniform riser heights exposing employees to trip hazards in the following areas but not limited to the stairs in plant 2, line 3 leading up between the north and south unit 2 reject tank, the risers on the second step from the ground were bent and damaged .
Recent events (2)
- — I (O) $3615.6
- — Z (S) $6026
1910.29 B05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.29(b)(5): Midrails, screens, mesh, intermediate vertical members, solid panels, and other equivalent intermediate members are capable of withstanding, without failure, a force of at least 150 pounds (667 N) applied in any downward or outward direction at any point along the intermediate member. a. On or about March 9, 2023, the employer did not ensure that the midrails of guardrail systems were capable of withstanding, without failure on the east catwalk adjacent C42 near weigh area, in plant 2 but not limited to, exposing employees to falls hazards due to the corrosion of railings and support structure for the railings. Pieces were missing due to corrosion and sections were separated from each other due to corrosion. b. On or about, and times prior to August 29, 2023, the employer did not ensure that the midrails of guardrail systems were capable of withstanding, without failure on the east catwalk adjacent C42 near weigh area, in plant 2 but not limited to, exposing employees to falls hazards due to the corrosion of railings and support structure for the railings. Pieces were missing due to corrosion and sections were separated from each other due to corrosion.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.29 F07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.29(f)(7): 29 CFR 1910.29(f)(7): Strength criteria. The employer did not ensure that handrails and the top rails of stair rail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in any downward or outward direction within 2 inches (5 cm) of any point along the top edge of the rail. a. On or about March 9, 2023, the employer did not ensure that top rails of stair rail systems were capable of withstanding, without failure, on the mixing area west stairwell landing, in plant 1 but not limited to, exposing employees to falls hazards due to the corrosion of railings and support structure for the railings. All structures in the area were not maintained according to the standard. Pieces were missing due to corrosion and sections were separated from each other due to corrosion. b. On or about, and times prior to August 29, 2023, the employer did not ensure that top rails of stair rail systems were capable of withstanding, without failure, on the mixing area west stairwell landing, in plant 1 but not limited to, exposing employees to falls hazards due to the corrosion of railings and support structure for the railings. All structures in the area were not maintained according to the standard. Pieces were missing due to corrosion and sections were separated from each other due to corrosion. c. On or about, and times prior to August 29, 2023, the employer did not ensure the top rails of the stair rail system in plant 2 but not limited to, the stairs from ground to mixing area on southside, was capable of withstanding minimum applied outward direction force, exposing employees to fall hazard due to damage of stair rail system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.29 K01 VI
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.29(k)(1)(vi): Are capable of withstanding, without failure, a force of at least 50 pounds (222 N) applied in any downward or outward direction at any point along the toeboard. a. On or about August 29, 2023, the employer did not ensure that the toeboard of guardrail systems were capable of withstanding, without failure on south catwalk adjacent C42 adjacent microbs, in plant 2 but not limited to, exposing employees to falls hazards due to the corrosion of railings and support structure for the railings. All structures in the area were not maintained according to the standard. Pieces were missing due to corrosion and sections were separated from each other due to corrosion.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at TOKAI CARBON CB, LTD.
ADDIS, LA—2025-03-31
TOKAI CARBON CB, LTD.
BORGER, TX—2024-09-04 00:00:00
TOKAI CARBON CB LTD.
BORGER, TX—2023-03-09 00:00:00
TOKAI CARBON CB, LTD.
BIG SPRING, TX—2023-01-12 00:00:00
TOKAI CARBON CB, LTD.
BIG SPRING, TX—2019-02-19 00:00:00
TOKAI CARBON CB, LTD.
View TOKAI CARBON CB, LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 335991)
MOORESVILLE, NC—2026-06-29
161449 - DEBOTECH, INC.
MOUNT HOPE, WV—2026-05-21
CARBON ACTIVATED CORP.
MINDEN, NV—2026-05-07
SOLUTION MARINE, LLC
MINDEN, NV—2026-05-04
SOLUTION MARINE, LLC
PARMA, OH—2026-02-23
EI6
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346556806.