OKLAHOMA CITY, OK —
OSHA Inspection: WACHTER, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of WACHTER, INC. in 100 E. INTERSTATE I-240 SERVICE ROAD, OKLAHOMA CITY, OK 73149 (NAICS 238210). OSHA activity number 346717853.
Where did this inspection happen?
- Establishment
- WACHTER, INC.
- Site address
- 100 E. INTERSTATE I-240 SERVICE ROAD
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73149
- Mailing
- 16001 W 99TH ST, LENEXA, KS 66219
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 1500
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury. On or about May 20, 2023, the employer did not assess the work site for unsafe work conditions and instruct the employees of the unsafe conditions. This exposed the employees to struck-by and electrical hazards.
Recent events (3)
- — F (S) $0
- — C (S) $15625
- — Z (S) $15625
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $8929.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns. a. On or about May 20, 2023, an employee was operating an aerial lift in the elevated position underneath trusses and beams near aisle I1 without a protective helmet. This exposed the employee to a struck-by and electrical hazard. b. On or about May 20, 2023, an employee was operating an aerial lift in the elevated position underneath trusses and beams without a protective helmet. This exposed the employee to a struck-by and electrical hazard.
Recent events (3)
- — F (S) $0
- — C (S) $8929
- — Z (S) $8929
1926.416 A03
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.416(a)(3): The employer began work without determining by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, is so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer did not post warning signs and advise employees of the location of the circuit, hazards, and protective measures they need to take. a. On or about May 20, 2023, an employee was performing work activities next to energized circuits such as single phase 277-volt light fixtures. This exposed the employee to an electrical hazard. b. On or about May 20, 2023, an employee was performing work activities next to energized circuits such as single phase 277-volt light fixtures. This exposed the employee to an electrical hazard.
Recent events (3)
- — F (S) $0
- — C (S) $15625
- — Z (S) $15625
1926.451 B02
- Issued
- Abate by
- Penalty
- Initial $15625.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: On or about May 20, 2023, an employee stepped onto the guardrail and toeboard of the mobile elevated work platform (MEWP) to elevate his work level height. The guardrail surface was not at least 18 inches wide and this exposed the employee to a fall hazard.
Recent events (3)
- — F (S) $0
- — C (S) $15625
- — Z (S) $15625
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On or about May 20, 2023, an employee used the guardrail and toeboard of the mobile elevated work platform (MEWP) to elevate his work level height. The employee was not in use of fall protection, and this exposed the employee to a fall hazard.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 G04 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(4)(ii): The top edge height on all suspended scaffolds where both a guardrail and a personal fall arrest system were not between 36 inches (0.9 m) and 45 inches (1.2 m) above the platform surface Note: For supported scaffolds manufactured and placed in service before January 1, 2000, and on all suspended scaffolds where both a guardrail and a personal fall arrest system are required, the top edge height should be between 36 inches (0.9 m) and 45. On or about May 20, 2023, an employee used the guardrail and toeboard of a mobile elevated work platform (MEWP) to elevate the working level height. This brought the employee above the guardrail system, exposing the employee to a fall hazard.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at WACHTER, INC.
LANCASTER, TX—2022-10-17 00:00:00
WACHTER, INC.
AFTON, TX—2022-06-15 00:00:00
WACHTER, INC.
LOS ANGELES, CA—2019-12-02 00:00:00
WACHTER INC.
KANSAS CITY, MO—2013-07-03 00:00:00
WACHTER, INC.
RENO, NV—2012-10-05 00:00:00
WACHTER, INC.
View WACHTER, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
WASHINGTON, IL—2026-07-17 00:00:00
SUNRUN INSTALLATION SERVICES, INC.
KAHULUI, HI—2026-07-16 00:00:00
RISING SUN SOLAR ELECTRIC LLC
PARKVILLE, MD—2026-07-15 00:00:00
THE POWER SOURCE, INC.
SOUTH BARRINGTON, IL—2026-07-15 00:00:00
EDGE ELECTRICAL SYSTEMS, LLC
More inspections in OK
TULSA, OK—2026-07-15 00:00:00
LA UNION 7 LLC
STILLWATER, OK—2026-07-13 00:00:00
LATSHAW DRILLING COMPANY
BROKEN ARROW, OK—2026-07-10 00:00:00
AMERICAN WHEATLEY
TINKER AFB, OK—2026-07-09 00:00:00
U.S. DEPARTMENT OF DEFENSE, TINKER AIR FORCE BASE
OCHELATA, OK—2026-07-08 00:00:00
WALMART, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346717853.