OLEAN, NY —
OSHA Inspection: BENSON CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BENSON CONSTRUCTION in 422 EAST STATE STREET, OLEAN, NY 14760 (NAICS 237110). OSHA activity number 346762412.
Where did this inspection happen?
- Establishment
- BENSON CONSTRUCTION
- Site address
- 422 EAST STATE STREET
- City
- OLEAN
- State
- NY
- ZIP
- 14760
- Mailing
- 130 SOUTH UNION STREET, OLEAN, NY 14760
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 C02
- Issued
- Penalty
- Initial $6250.00 · Current $4688.00 Reduced
General-duty citation text
29 CFR 1926.651(c)(2):Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees; a) On or about 6/6/23 at a water line project located at 422 East State Street, Olean, New York; employees were in an excavation to replace a fire hydrant. Employees were in and excavation approximately 5'-5" deep without a ladder or other proper means of egress. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4687.5
- — Z (S) $6250
1926.652 A01
- Issued
- Penalty
- Initial $7813.00 · Current $5860.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): 29 CFR 1926.652(a)(1) Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): a) On or about 6/6/23 at a water line project located at 422 East State Street, Olean, New York; employees were in an excavation to replace a fire hydrant. The excavation was approximately 5'-5" deep in the work area with vertical walls and was not properly protected from cave-ins. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $5859.75
- — Z (S) $7813
More inspections at BENSON CONSTRUCTION
ELK GROVE, CA—2012-08-16 00:00:00
BENSON CONSTRUCTION
New Port Richey, FL—1982-05-18
BENSON CONSTRUCTION
View BENSON CONSTRUCTION's full OSHA safety record →
More inspections in this industry (NAICS 237110)
CHESAPEAKE, VA—2026-07-10
A&W CONTRACTORS, INC.
BRIDGEPORT, CT—2026-07-10
WRR, INC.
MARYSVILLE, WA—2026-07-09
WA317992011 - BDZ DEVELOPERS INC
PEORIA, IL—2026-07-08
WALTERS WATERWORKS LLC DBA MR. ROOTER PLUMBING OF PEORIA
TAMPA, FL—2026-07-08
DALLAS 1 CONSTRUCTION AND DEVELOPMENT, INC.
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346762412.