BARTLETT, IL —
OSHA Inspection: PLATINUM CONVERTING INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PLATINUM CONVERTING INC. in 1560 WEST STEARNS ROAD, BARTLETT, IL 60103 (NAICS 561910). OSHA activity number 346974421.
Where did this inspection happen?
- Establishment
- PLATINUM CONVERTING INC.
- Site address
- 1560 WEST STEARNS ROAD
- City
- BARTLETT
- State
- IL
- ZIP
- 60103
- Mailing
- 1560 WEST STEARNS ROAD, BARTLETT, IL 60103
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561910
- Employees
- 164
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Penalty
- Initial $14063.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolate: (a) On or about September 2, 2023, the employer did not ensure that all PMC Model 200 Die Cutting Machine employees who perform service and maintenance such as cleaning trim waste buildup inside the discharge chute where dies are present of the machine were adequately trained as "authorized" employees. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $14063
1910.212 A03 III
- Issued
- Penalty
- Initial $0.00 · Current $7500.00
General-duty citation text
1910.212(a)(3)(iii) Special hand tools for placing and removing material(s) was not provided to permit easy handling of material without the operator placing a hand in the danger zone: (a) On or about September 2, 2023, the employer did not ensure that employees used tongs when placing trim waste that had been discharged from the PMC Model 200 Die Cutter machine into the waste container. The employer did not implement energy control application steps as the machines were not shut down or turned off to clear out scrap from the equipment [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine hazards. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $7500
- — Z (S) $0
More inspections at PLATINUM CONVERTING INC.
ITASCA, IL—2017-10-05 00:00:00
PLATINUM CONVERTING, INC.
View PLATINUM CONVERTING INC.'s full OSHA safety record →
More inspections in this industry (NAICS 561910)
WESTBROOK, ME—2026-06-23
CAPSTONE LOGISTICS
KANSAS CITY, MO—2026-06-19
ADVANCED LOGISTICS & FULFILLMENTS
CHATSWORTH, CA—2026-06-12
HNV HOLDING LLC
FORT ATKINSON, WI—2026-06-11
A-1 CREATIVE PACKAGING, LLC
SIMPSONVILLE, SC—2026-05-14
77476 - SOUTH EASTERN CORRUGATED
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346974421.