FRANKLIN, OH —
OSHA Inspection: FAURECIA EMISSIONS CONTROL SYSTEMS NA, LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of FAURECIA EMISSIONS CONTROL SYSTEMS NA, LLC in 2301 COMMERCE CENTER DR., FRANKLIN, OH 45005 (NAICS 336390). OSHA activity number 347033433.
Where did this inspection happen?
- Establishment
- FAURECIA EMISSIONS CONTROL SYSTEMS NA, LLC
- Site address
- 2301 COMMERCE CENTER DR.
- City
- FRANKLIN
- State
- OH
- ZIP
- 45005
- Mailing
- 2301 COMMERCE CENTER DRIVE, FRANKLIN, OH 45005
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336390
- Employees
- 345
- Ownership type
- A
Citations
16 citations on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $16131.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.? ? (A) The periodic inspection shall be performed by an authorized employee other than the ones(s) utilizing the energy control procedure being inspected.? ? (B) The periodic inspection shall be conducted to correct any deviations or inadequacies identified.? ? (C) Where lockout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.? ? a) On or about October 14, 2023, the employer did not conduct periodic inspections for each energy control procedures at least annually for equipment such as benders, sizers, and presses.
Recent events (2)
- — I (S) $16131
- — Z (S) $16131
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $16131.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: ? ? (A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.? ? a) On or about October 13, 2023, Set-up technician #11 was not trained as an authorized employee for the proper use of energy control procedures and how to safely shutdown machines and when to isolate energy sources such as electric, pneumatic and hydraulic for equipment including benders and sizers prior to performing servicing and maintenance tasks such as but not limited to changing wipers on benders, changing blades on benders, changing mandrel cables benders,?tooling changeovers on benders, and adjustments on sizers.? ? On October 26, 2023, Set-up Technician #11 was performing a changeover on Bender 26 and only isolated the electrical power to the machine leaving pneumatic source pressurized thereby not following the energy control procedure for safe control of hazardous energy.
Recent events (2)
- — I (S) $16131
- — Z (S) $16131
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: ? ? (A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.? ? a) On or about October 12, 2023, Set-up technician #24 was not trained as an authorized employee for the proper use of energy control procedures and how to safely shutdown machines and when to isolate energy sources such as electric, pneumatic and hydraulic energy sources for equipment including but not limited to benders, sizers, and cut offs?prior to performing servicing or maintenance activities such as but not limited to setting up collets blocks (guides on benders), changing wipers on benders, changing blades on benders, changing mandrel cables on and performing bender tooling changeovers on benders.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: ? ? (A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.? ? a) On or about October 12, 2023, Set-up technician #25 was not trained as an authorized employee for the proper use of energy control procedures and how to safely shutdown machines and when to isolate energy sources such as electric, pneumatic and hydraulic energy sources for equipment including but not limited to benders, sizers, and cut offs?prior to performing servicing or maintenance activities such as but not limited to setting up collets blocks (guides on benders), changing wipers on benders, changing blades on benders, changing mandrel cables on and performing bender tooling changeovers on benders.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: ? ? (A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.? ? a) On or about October 12, 2023, Set-up technician #21 was not trained as an authorized employee for the proper use of energy control procedures and how to safely shutdown machines and when to isolate energy sources such as electric, pneumatic and hydraulic energy sources for equipment including but not limited to benders, sizers, and cut offs?prior to performing servicing or maintenance activities such as but not limited to setting up collets blocks (guides on benders), changing wipers on benders, changing blades on benders, changing mandrel cables on and performing bender tooling changeovers on benders.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $16131.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: ? ? (A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.? ? a) On or about October 13, 2023, bender operator #3 was not trained as an authorized employee in the recognition of applicable hazardous energy sources, methods and means necessary for energy isolation and control prior to changing wipers, blades and clamps, and TPM servicing and maintenance on equipment to include handfed benders.
Recent events (2)
- — I (S) $16131
- — Z (S) $16131
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: ? ? (A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.? ? a)? On or about October 13, 2023, bender operator #4 was not trained as an authorized employee in the recognition of applicable hazardous energy sources, methods and means necessary for energy isolation and control prior to changing wipers, blades and clamps, and TPM servicing and maintenance on equipment to include handfed benders.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: ? ? (A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.? ? a) On or about October 13, 2023, Bender Operator #10 was not trained as an authorized employee for the proper use of energy control procedures and how to safely shutdown machines and when to isolate energy sources such as electric, pneumatic and hydraulic energy sources for equipment including but not limited to benders prior to performing servicing or maintenance activities such as but not limited to changing wipers on benders, changing blades on benders, and performing daily cleaning of benders.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $16131.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: ? ? (A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.? ? a) On or about October 13, 2023, Gap Leader #13 was not trained as an authorized employee for the proper use of energy control procedures and how to safely shutdown machines and when to isolate energy sources such as electric, pneumatic and hydraulic energy sources for equipment including but not limited to benders prior to performing servicing or maintenance activities such as but not limited to changing wipers on benders, changing blades on benders, and performing daily TPM cleaning and maintenance.
Recent events (2)
- — I (S) $16131
- — Z (S) $16131
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: ? ? (A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.? ? a) On or about October 13, 2023, Gap Leader #7 was not trained as an authorized employee for the proper use of energy control procedures and how to safely shutdown machines and when to isolate energy sources such as electric, pneumatic and hydraulic energy sources for equipment including but not limited to benders prior to performing servicing or maintenance activities such as but not limited to changing wipers on benders, changing blades on benders, and performing daily TPM cleaning and maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: ? ? (A) Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.? ? a) On or about October 13, 2023, Gap Leader #23 was not trained as an authorized employee for the proper use of energy control procedures and how to safely shutdown machines and when to isolate energy sources such as electric, pneumatic and hydraulic energy sources for equipment including but not limited to benders prior to performing servicing or maintenance activities such as but not limited to changing wipers on benders, changing blades on benders, and performing daily TPM cleaning and maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
1910.147 C07 III A
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(iii)(A): Retraining shall be provided for all authorized and affected employees whenever there is a change in their job assignments, a change in machines, equipment or processes that present a new hazard, or when there is a change in the energy control procedures. a) On or about October 14, 2023, employees did not receive retraining after maintenance technicians performing service and maintenance tasks deviated from the energy control procedures for benders. Maintenance technicians locked E-stops and interlocked doors for cells versus following the documented machine specific lockout procedures.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $16131.00
General-duty citation text
29 CFR 1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:? ? (d)(1) Preparation for shutdown. Before an authorized or affected employee turns off a machine or equipment, the authorized employee shall have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy.? ? (d)(2) Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.? ? (d)(3) Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).? ? (d)(4) Lockout or tagout device application.? ? (d)(4)(i) Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.? ? (d)(4)(ii) Lockout devices, where used, shall be affixed in a manner to that will hold the energy isolating devices in a "safe" or "off" position.? ? (d)(5) Stored energy.? ? (d)(5)(i) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe.? ? (d)(5)(ii) If there is a possibility of reaccumulation of stored energy to a hazardous level, verification of isolation shall be continued until the servicing or maintenance is completed, or until the possibility of such accumulation no longer exists.? ? (d)(6) Verification of isolation. Prior to starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergization of the machine or equipment have been accomplished.? ? a) On or about October 12, 2023, employees were exposed to machine hazards associated with moving parts during changeovers, wiper die changes, clamp changes, blade changes, TPMs, and the cleaning of benders. The employer did not ensure employees implemented energy control application steps (d)(1) through (d)(6) prior to conducting servicing and maintenance on equipment.
Recent events (2)
- — I (S) $16131
- — Z (S) $16131
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $16131.00
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.? ? a) On or about October 14, 2023, located in the Bending Area, employees operated an Addition Manufacturing handfed Bender #31 that was not guarded to protect the employees from moving parts of the bender exposing the employees to caught-between and struck-by hazards.?? On October 14, 2023, Employee #1 was placing cardboard on the floor under Bender #31 which was an area that was not being detected by a Keyence Safety Laser Scanner. The bender was restarted by another employee causing the bend arm to close on Employee #1 resulting in death. b) On or about October 14, 2023, located in the Bending Area, employees operated an Addition Manufacturing handfed Bender #16 that was not guarded to protect the employee from moving parts of the bender exposing the employees to caught-between and struck-by hazards. c) On or about October 14, 2023, located in the Bending Area, employees operated an Addition Manufacturing handfed Bender #23 that was not guarded to protect the employees from moving parts of the bender exposing the employees to caught-between and struck-by hazards. d) On or about October 14, 2023, located in the Bending Area, employees operated an Addition Manufacturing handfed Bender #24 that was not guarded to protect the employees from moving parts of the bender exposing the employees to caught-between and struck-by hazards. e) On or about October 14, 2023, located in the Bending Area, employees operated an Addition Manufacturing handfed Bender #28 that was not guarded to protect the employees from moving parts of the bender exposing the employees to caught-between and struck-by hazards.
Recent events (4)
- — P (S) $16131
- — P (S) $16131
- — I (S) $16131
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $88721.00 · Current $16131.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:? ? (A) A specific statement of the intended use of the procedure;? (B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;? ? (C) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and? ? (D) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.? ? a) On or about October 13, 2023, the employer did not ensure that machine specific energy control procedures for benders included the rules for the application of the procedure, the magnitude of hydraulic and pneumatic energy sources, a specific statement of the intended use for each procedure, specific procedural steps for the safe shutdown, specific procedural steps for removal and transfer of locks, and the means to enforce compliance as required by paragraphs (A through D).? Faurecia Emissions Control Systems NA, LLC was previously cited for a violation of its equivalent Occupational Safety and Health standard 1910.147(c)(4)(ii)(B), which was contained in OSHA inspection number 1554291, citation number 1, item number 2 and was affirmed as a final order on January 26, 2022, with respect to a workplace located at 2301 Commerce Center Drive Franklin, OH 45005.
Recent events (2)
- — I (S) $16131
- — Z (R) $88721
1910.147 C06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.? ? a) On and before October 14, 2023, the employer did not ensure that the periodic inspections being certified were conducted correctly in that only bender machines in the facility were inspected. The periodic inspections conducted by maintenance employees did not include the energy control procedures being utilized, the dates of was properly certified correctly in that maintenance employees did not conduct the periodic inspection utilizing the energy control procedures for benders, The periodic inspections being conducted did not list what equipment on of all energy control procedures were conducted, and did not certify that the procedures that were completed by authorized employees identified the machine or equipment being inspected.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at FAURECIA EMISSIONS CONTROL SYSTEMS NA, LLC
FRANKLIN, OH—2023-11-07 00:00:00
FAURECIA EMISSIONS CONTROL SYSTEMS NA, LLC
FRANKLIN, OH—2021-10-01 00:00:00
FAURECIA EMISSIONS CONTROL SYSTEMS NA, LLC
FRANKLIN, OH—2021-09-21 00:00:00
FAURECIA EMISSIONS CONTROL SYSTEMS NA, LLC
ARLINGTON, TX—2020-10-21 00:00:00
FAURECIA EMISSIONS CONTROL SYSTEMS NA, LLC
FRANKLIN, OH—2019-05-07 00:00:00
FAURECIA EMISSIONS CONTROL SYSTEMS NA, LLC
View FAURECIA EMISSIONS CONTROL SYSTEMS NA, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336390)
OGDEN, UT—2026-07-14
EXPEDITION ONE LLC
CIRCLEVILLE, OH—2026-07-07
ENGINEERED PLASTIC COMPONENTS INC.
BENTON HARBOR, MI—2026-06-30
LINAMAR STRUCTURES GROUP
NEW HUDSON, MI—2026-06-30
COSMA BODY ASSEMBLY MICHIGAN
OGDEN, UT—2026-06-23
AUTOLIV ASP INC
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347033433.