Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: TRENWA, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TRENWA, INC in 34229 SUNSET LANE, BROOKSHIRE, TX 77423 (NAICS 327390). OSHA activity number 347095820.

Watch Trenwa, INC — free Get an email when a new federal OSHA severe-injury report for Trenwa, INC is published. One employer, no account, unsubscribe in one click.
Establishment
TRENWA, INC
Site address
34229 SUNSET LANE
City
BROOKSHIRE
State
TX
ZIP
77423
Mailing
34229 SUNSET LANE, BROOKSHIRE, TX 77423
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
22
Ownership type
A

4 citations on file for this inspection.

1910.37 A03

Serious Gravity 1 1 instance 22 exposed
Issued
Abate by
Penalty
Initial $4839.00 · Current $2903.00 Reduced
29 CFR  1910.37(a)(3):Exit route(s) were not kept free and unobstructed:  On or about October 26, 2023, at the lid area employees were exposed to fire hazards as an exit door was blocked by concrete bases and other equipment.
Recent events (2)
  • — I (S) $2903.4
  • — Z (S) $4839

1910.178 P01

Serious Gravity 5 2 instances 22 exposed
Issued
Abate by
Penalty
Initial $6453.00 · Current $3872.00 Reduced
29 CFR  1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s).  On or about September 8, 2023, at the yard of facility an employee was operating a forklift in need of repair such as but not limited to:  a.	Cracked windshield on Hyundai forklift Model: 70D-9 which was not taken out of service.  b.	Forklift that did not have seatbelt repaired on Hyundai forklift Model: 70D-9.
Recent events (2)
  • — I (S) $3871.8
  • — Z (S) $6453

1910.334 A02 I

Serious Gravity 5 1 instance 22 exposed
Issued
Penalty
Initial $6453.00 · Current $3872.00 Reduced
29 CFR  1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  On or about November 8, 2023, at the lid area of facility employees were exposed to electrical hazards as there were two angle grinders that had frayed cords and were not visually inspected.
Recent events (2)
  • — I (S) $3871.8
  • — Z (S) $6453

1910.303 F02

Other-than-serious 1 instance 22 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(f)(2):Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  On or about November 8, 2023 at the lid area there was an electrical breaker box which did not have it switches labeled.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View TRENWA, INC's full OSHA safety record →