Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: RED DIAMOND ENERGY SERVICES, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of RED DIAMOND ENERGY SERVICES, INC. in BTA DUCK POND 219010 36-25-2H 32.094895, -101.866780, STANTON, TX 79782 (NAICS 213112). OSHA activity number 347099848.

Watch RED Diamond Energy Services, INC. — free Get an email when a new federal OSHA severe-injury report for RED Diamond Energy Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
BTA DUCK POND 219010 36-25-2H 32.094895, -101.866780
City
STANTON
State
TX
ZIP
79782
Mailing
PO BOX 7269, ABILENE, TX 79608
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
4
Ownership type
A

2 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13308.00 · Current $13308.00
29 CFR  1910.28(b)(1)(i):   Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i)(A)-(C):  On or about November 10, 2023, employees engaged in well servicing activities at the oil and gas lease site were exposed to fall hazards while working on the tubing board in excess of four feet.
Recent events (3)
  • — R (S) $13308
  • — C (S) $13308
  • — Z (S) $13308

1910.140 C17

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.140(c)(17): 29 CFR 1910.140(c)(17): The employer did not ensure that a personal fall protection system or its components subjected to impact loading is removed from service immediately and not used again until a competent person inspects the system or components and determines that it is not damaged and safe for use for employee personal fall protection.  On or about November 10, 2023, employees engaged in well servicing activities at the oil and gas lease site were exposed to fall hazards while using a personal fall protection system that had been subjected to impact loading and had not been removed from service immediately.
Recent events (3)
  • — R (S) $0
  • — C (S) $0
  • — Z (S) $0

View RED DIAMOND ENERGY SERVICES, INC.'s full OSHA safety record →