NORTH TONAWANDA, NY —
OSHA Inspection: WESTROCK CP LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of WESTROCK CP LLC in 51 ROBINSON ST, NORTH TONAWANDA, NY 14120 (NAICS 322211). OSHA activity number 347221111.
Where did this inspection happen?
- Establishment
- WESTROCK CP LLC
- Site address
- 51 ROBINSON ST
- City
- NORTH TONAWANDA
- State
- NY
- ZIP
- 14120
- Mailing
- 51 ROBINSON ST, NORTH TONAWANDA, NY 14120
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322211
- Employees
- 129
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.145 C02 I
- Issued
- Abate by
- Penalty
- Initial $16131.00 · Current $16131.00
General-duty citation text
1910.145(c)(2)(i) Caution signs shall be used only to warn against potential hazards or to caution against unsafe practices. 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 01/18/2024, in the production area; where energy control procedures for the non-routine task of removing the die-cut drum from the LANGSTON TITAN Rotary Die Cutter machine (machine number 4561/784) did not include the potential energy of the raised weight (the 4000 pound die-cut drum) in the types and magnitude of energy available on the machine. ABATEMENT DOCUMENTATION REQUIRED
Recent events (3)
- — F (S) $16131
- — C (S) $16131
- — Z (S) $16131
1910.147 D05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: a) On or about 01/18/2024 on the LANGSTON TITAN Rotary Die Cutter (machine number 4561/784); where potential energy from a raised weight (the die cut drum) was not restrained before disconnecting the bolts which secured the die cut drum to the machine frame and prying the die cut drum out of the frame of the machine. The die cut drum was attached to the "free wheeling" print down with rigging straps and a chain fall. When the die cut drum was rolled off the polyurethane anvil drum, it pulled the print down forward, creating a crushing action between the stationary die cut stand and the free wheeling print down. Employees were exposed to the crush point between the two parts of the machine. ABATEMMENT DOCUMENTATION REQUIRED
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at WESTROCK CP LLC
MILWAUKEE, WI—2026-05-19
WESTROCK CP, LLC
RAVENNA, OH—2026-03-17
WESTROCK CP, LLC
WEST POINT, VA—2026-03-05
WESTROCK CP, LLC
DUBLIN, GA—2026-01-07
WESTROCK CP, LLC
FRESNO, CA—2025-11-12
WESTROCK CP, LLC
View WESTROCK CP LLC's full OSHA safety record →
More inspections in this industry (NAICS 322211)
SAVAGE, MN—2026-07-08
111557 - BF NELSON CORPORATION
WEST CHESTER, OH—2026-07-08
GEORGIA PACIFIC CORRUGATED LLC
ALBERT LEA, MN—2026-07-01
111514 - INTERSTATE PACKAGING CORPORATION
STURTEVANT, WI—2026-07-01
ND PACKAGING LLC
FILER CITY, MI—2026-06-29
PACKAGING CORPORATION OF AMERICA
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347221111.