1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: FLUID ROUTING SOLUTIONS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FLUID ROUTING SOLUTIONS LLC in 3100 SE MARICAMP RD, OCALA, FL 34471 (NAICS 326220). OSHA activity number 347294340.

Watch Fluid Routing Solutions LLC — free Get an email when a new federal OSHA severe-injury report for Fluid Routing Solutions LLC is published. One employer, no account, unsubscribe in one click.
Site address
3100 SE MARICAMP RD
City
OCALA
State
FL
ZIP
34471
Mailing
3100 SE MARICAMP RD, OCALA, FL 34471
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326220
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $11292.00 · Current $6775.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   a.) At the worksite, located at 3100 SE Maricamp RD Ocala, FL 34471; On or about 2/15/24, the employer exposed employees to caught in hazards, in that, guarding mechanisms were not in place while employees operated the rotating Mandrel #2 hose machine, wrapping hose line around the reel.
Recent events (2)
  • — I (S) $6775.2
  • — Z (S) $11292

1910.37 B04

Other-than-serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $4839.00 · Current $2903.00 Reduced
29 CFR  1910.37(b)(4):Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:  a.) At the worksite, located at 3100 SE Maricamp RD Ocala, FL 34471; On or about 2/21/24, the employer exposed employees to fire and smoke inhalation hazards, in that emergency evacuation signage along the warehouse was not utilized and provided for employees while performing machine operations in the production and finishing area.
Recent events (2)
  • — I (O) $2903.4
  • — Z (S) $4839

View FLUID ROUTING SOLUTIONS LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347294340.